Last updated: 2026-11-27. Hand checks waiting for a person at the screen. An item is added when a fix is merged and removed when it has been checked; anything that fails goes back to its issue. "In build" is the first commit that contains the fix: the package you test must be that build or later.

How to help: anyone can take an item. Install the build named (packages from the latest CI run on main, or build as in GETTING_STARTED.md), follow "How to test", and comment on the linked issue: what you did, what you saw, operating system and version, and a screenshot if something looks wrong.

9.6.1 fixes to check by hand

9.6.1 was released on 2026-11-27. These are its fixes that need a person at the screen; the rows below this section are from earlier rounds. Everything here is in the released 9.6.1 packages.

Check How to test What to look for Issue In build
Generate Bonds after a save is kept File > Open Example Calculations..., General Chemistry; select h2o_dimer (Examples > Intermolecular interactions) and open the Builder. Save (Ctrl+S). Then Build > Generate Bonds, and close the Builder's tab with its ×. Closing asks whether to save the change made by Generate Bonds. Answer Save, reopen the Builder: the generated bonds are there and the nubs are gone. Before the fix the tab closed without asking and the change was lost. #1308 v9.6.1
An untouched Builder is not marked modified Open the Builder on h2o_dimer (General Chemistry) and change nothing. Leaving that tab open, go back to the Organizer and open the Viewer of a different calculation, e.g. HF_dipole (General Chemistry > Polar bonds and dipole moments). Then close the h2o_dimer Builder tab with its ×. The Builder closes without asking to save. Note that the Periodic Builder, Slice, Trajectory, Scan and Point Calculation panels are not covered by this fix, so a change announced from one of those can still mark another Builder modified. #1307 v9.6.1
Warning when the docking box holds no receptor The imatinib Vina calculation on 1IEP from the row "Vina scoring function and panel width" below. In the Builder add the ligand from a separate file instead of using the one in the receptor's structure (File > Add Structure from File..., the ligand's .xyz or .pdb), select it as the ligand in Runtype Details, Save, and Launch. Launch shows a warning naming how many receptor atoms are inside the search box (almost none) and pointing at Tools > Docking Box Around Selection. The warning does not block: launching anyway is still possible. With the ligand taken from 1IEP itself, no warning appears. #1296 v9.6.1
Docking poses open at once and their labels can be read The same 1IEP imatinib Vina calculation, after it has finished: open its poses in the Viewer and look at the residue labels around the pocket. The poses appear within seconds, not minutes. The residue labels are in the Foreground colour and are readable against the background (they were white on white). #1293 v9.6.1
Carbon monoxide gets a triple bond from Clean New calculation, Builder: draw a carbon and an oxygen and join them (or Add from SMILES [C-]#[O+]), then Build > Clean. The bond is drawn as a triple bond and the Clean report reads C1#O2 triple (both terminal; uses a lone pair, C1-/O2+). Check a nitrile (e.g. SMILES CC#N) in the same way: it is unchanged. #1292 v9.6.1
Dragging in the Organizer tree Organizer: create a second project under Local data, then drag Solids > diamond_r2 onto it; drag a folder onto another folder as well. The drag starts on the first press, the item moves, and no gtk_drag_begin: assertion ... failed line appears in the terminal. #983 v9.6.1
Substitution vs elimination examples have their orbitals Organic Chemistry > Substitution vs elimination > f_etcl_sn2_irc, and then f_etcl_e2_irc, in the Viewer. Properties: Density Map, and the MO panel's composition. Both open with a basis and orbitals: Density Map draws, and MO composition lists contributions. (These are the regenerated examples; a copy made from an older installation still lacks them.) #1211 v9.6.1
Calculation Editor fits a 768-pixel screen On a screen 768 pixels high (or a display set to 1366x768), open the Calculation Editor of the benzene example. The whole editor is on the screen: its bottom row of buttons is visible without moving the window. #189 v9.6.1
Diffraction readout reaches a script Solids > urea_r2, Properties > Diffraction, View: Detector. Rest the pointer on a spot, then click it. The readout line under the image names the reflection, its multiplicity and the structure factor for both hover and click. (A script using the xrd hover/xrd click hooks gets the same text; this check is the visible half.) #1282 v9.6.1
Windows: command-line tools and drive-letter files On Windows, with ECCE running: open a Command Prompt in some folder other than ECCE's own (e.g. C:\Users\<you>) and run ecce-import on an output file there; then, from the file manager, open a structure file on a drive other than C: with Open With > ECCE. The command reaches the running Organizer from any folder, and the structure from the other drive opens in the Builder instead of failing on its drive letter. #1287, #1289 v9.6.1

Next round: layouts (at most 10)

Checks that need a person: does it look right and work by hand. The rest of this page is checked by Claude with the test hooks first.

Check How to test What to look for Issue In build
SSH folder listing keeps the window usable Organizer with an SSH folder on another machine, already connected and shown in the tree (connect it first and wait until its top level is listed). Then double-click one of its sub-folders that has not been opened since ECCE started. Connecting the folder itself (the first connect after starting ECCE) still blocks the window for one round trip; that is #1303, not this check. The window stays usable while the sub-folder is listed. If the listing takes longer than about 1 s, a bar "Listing ..." with Cancel appears between the tree and the message area; on a quick host the listing finishes before the bar shows, which is expected. Pressing Cancel while the bar shows leaves the sub-folder unopened. #1220 31caa9f79
Playback Repeat Organic Chemistry > Substitution vs elimination > f_etcl_sn2_irc, Viewer, IRC Path panel. Set Repeat: to off, then from the start, then back and forth, pressing Play each time. off: stops at the last frame; from the start: jumps back to the first frame and plays on; back and forth: plays back to the start and forward again. #1229 01b7641b3
MINFF substitutions and genion New GROMACS calculation, Builder: a montmorillonite stack in the Layer Builder. In GROMACS Prepare ask for more substitutions than the cell has sites; run Prepare. Then set a very small Water layer above the mineral and run Prepare again. The summary says how many substitutions were made of those asked and what to change; the second run names the fields to change (Water layer above the mineral / Distance to edge, Minimum ion distance) instead of genion's own message. #1228, #1280 01b7641b3
Vina scoring function and panel width The imatinib Vina calculation from the row "Vina: dock a ligand in a receptor" (1IEP): Theory Details, Scoring function vinardo; Launch. Then Runtype Details. The run uses vinardo (the output says so; with a Vina older than 1.2 it warns and uses vina). Runtype Details fits the right panel without a horizontal scroll bar. #1278 01b7641b3
Native file window for Open and Add Structure Builder on the benzene example: File > Open..., then File > Add Structure from File...; choose a .xyz file in your home folder. Then File > Open from Remote Machine.... The first two use the desktop's own file window and open in the folder used last time; the remote item shows ECCE's old dialog. #342 01b7641b3
Window not greyed while a tool opens Organizer: open the Calculation Editor of the benzene example, then launch it. The main window and its tabs stay in colour while the status line says the tool is starting and while the launch runs. #1268 01b7641b3
Tabs: tooltips, Next/Previous Tab, Window list Open Viewers for two calculations and the Calculation Editor for one of them. Rest the pointer on each tab; press Ctrl+Tab and Ctrl+PgDn/PgUp; open the Window menu and choose an entry; open the same Editor again from the Organizer. Each tab's tooltip shows its calculation's path and tool; the keys step through the tabs and wrap; the Window menu lists every tab with its path and selecting one switches to it; the second Editor start switches to the existing tab. #1256 de9d3d774
Diffraction not the default; Cancel Open 181L.pdb from the file manager: the Builder opens on the structure, not on a diffraction pattern. Then Properties > Diffraction, View: Detector. No calculation starts until Diffraction is chosen; a slow pattern shows a progress row with Cancel, and Cancel stops it. #1245, #1246 f98cdc8dc
Tab x closes on the first click Open a Viewer, a Builder and a Calculation Editor as tabs; move the pointer from the 3-D view straight to each tab's x and click once. Each tab closes on the first click. #1234 6021c1ef6
Vina preview and Runtype Details New calculation, code Vina, on a structure with protein and ligand (e.g. the docking example); before saving, look at the input preview; then press Runtype Details. The preview shows Vina's config (receptor, ligand, center_x ...), not 'no theory yet'; while Runtype Details opens, the editor does not flicker and the note above the preview does not change back and forth. #1261 fcf8746c9
Add Hydrogen without residues and on mixed structures (a) Open an XYZ or CIF with heavy atoms only (e.g. benzene without H), Build > Add Hydrogen. (b) Open 181L.pdb, draw one carbon in empty space (answer the residue question with Insert), Build > Add Hydrogen. (a) Hydrogens on every C, N, O as the geometry implies. (b) The protein and the drawn carbon both get hydrogens; no crash. #1251 bbc31ff50
IRC: Show MO while playing greyed out Organic Chemistry > Substitution vs elimination > f_etcl_sn2_irc, Viewer, IRC Path panel. "Show MO while playing" is greyed out; its tooltip says to store orbitals at every point (Runtype Details). #1211 8abc6582f
MO Diagram: split pair clickable Any example with a near-degenerate orbital pair (e.g. benzene), Viewer, MO Diagram; hover and click each orbital of the pair. Each orbital of the pair can be clicked; a merged level says so on hover. #1212 8abc6582f
No tooltip over diffraction images Solids > urea_r2, Properties > Diffraction, View: Detector; rest the pointer on a spot. Only the spot readout appears; no box with the zoom and pan controls covers it. #1255 3e1641b79
Vina ligand list Open 181L.pdb from the file manager; Edit > Select Solvent, Delete; Build > Add Hydrogen; save as a Vina docking calculation; open Runtype Details. A list of the structure's molecules (LIG/ligands first); the first is selected and its atoms fill the ligand field without typing atom numbers. #1244 b4562b256
Properties list clicks Open the benzene example in the Viewer, Properties tab. Click MOs, then Surfaces, then Density Map, with the list scrolled as well as unscrolled. Each click selects the row clicked; the list does not jump between rows. #965 5bb780bad
Selected atom shown in the view Open any structure, click one atom, then Shift-click a second. Bottom left of the 3-D view: element, number and x y z of the atom; with two atoms, their distance. #1236 34334533e
Run-state icons and Periodic Builder row Look at the Run States legend at the bottom of the Organizer; open Solids > diamond_r2 > Periodic Builder. The icons have no light square behind them; the replication fields show a, b, c fully with 'Uniform' on its own row, no stray box or 'b:'. #1241, #1243 34334533e
Add Hydrogen and Select Ligand on a PDB 181L.pdb: Build > Add Hydrogen; then Edit > Select Ligand ▸. Status line: about 1300 hydrogens added, none to HOH and CL; the benzene has six H in its plane. The submenu lists BNZ 400 first, then HED 170 and the two CL. #1244 ed7d15401
Builder thumbnails Select Solids > diamond_r2 in the Organizer, click another calculation, then diamond_r2 again. The Builder button shows the diamond structure instead of the generic icon (from the second selection on). #1238 eb764f89f
Replicates with Centre lattice Solids > diamond_r2: Builder > Periodic Builder, Centre lattice ticked, raise replicates to 2 2 2. All atoms inside the drawn replicated cell. #1235 eb764f89f
No crash in the Window menu With tabs, open the Window menu and move the mouse up and down over its items several times. No crash. #1239 eb764f89f
Second start without a password (local mode) Start ecce (your own data server, no -remote). Sign in. In a second terminal run ecce again. The second ecce returns at once with "already running"; no password window; the running Organizer comes to the front. #1069 f6f570dc0
Basis panel replaces the Basis Set Tool window File > Open Example Calculations..., General Chemistry, OK. Select HF_dipole (Polar bonds and dipole moments) and Duplicate it. Click the Organizer's Basis Set button. In the panel tick only F, pick def2-TZVP, click Assign to checked elements; then tick only H, pick def2-SVP, Assign to checked elements. Save, then View Input. The editor opens at its basis panel (no separate Basis Set Tool window); Tools has no Basis Set Tool...; the input has def2-TZVP on F and def2-SVP on H. #1063 076992a20
Layer Builder stack as a GROMACS MINFF system New GROMACS calculation, Builder: Build a montmorillonite stack in the Layer Builder (three layers, Na⁺ and water in the gaps). In GROMACS Prepare pick the Mineral source, Mineral from: the Builder, then run Prepare, Optimize, Equilibrate (NVT) and Dynamics (NPT) with defaults. Prepare adds no extra water layer and shows the stack's own waters and ions; every step completes; the NPT run does not crash and the layers stay intact. #1140 c2649ab22
Solvate in the Builder New calculation, Builder: Add from SMILES CO (methanol). Build > Solvate..., water216, margin 8 Å, OK. Then Edit > Undo. Methanol in a box of water with a periodic cell; no water overlapping the methanol; Undo brings back methanol alone, no crash. #1118 09fb4bb7b
One program by default; second start; Quit Start plain ecce (no variable). File > Open Example Calculations..., General Chemistry, OK. Select h2o_dimer (Examples > Intermolecular interactions) and open the Builder. In a second terminal run ecce again. Then File > Quit. Builder opens as a tab in the Organizer's window; the second ecce returns at once and the running window comes to the front; Quit closes everything and the terminal prompt returns. #1067 bde9b56fd
Builder tab on a run calculation With plain ecce, select h2o_dimer (a completed calculation) and open the Builder (not the Viewer), then the Viewer. The Builder's tab says Builder, the Viewer's Viewer. #1106 bde9b56fd
Tabs: repeat click, closing a tool tab (one program) Start with ECCE_ONE_PROCESS=1 ecce. File > Open Example Calculations..., General Chemistry, OK. Select h2o_dimer (Examples > Intermolecular interactions), open it in the Builder, then click the Builder icon again; open the Viewer. Close the Builder's tab with its ×, save the structure in another tab and look at which tab is in front. The second click selects the open Builder tab (no second tab); the Viewer opens as a tab; closing a tool tab closes only that tool and never asks to quit ECCE; after Save the same tab stays in front; while a tool starts, the window ignores clicks but is not greyed #1088 dd3afc022
Viewer tab title; no save question from an unchanged Basis Set Tool (one program) Start with ECCE_ONE_PROCESS=1 ecce. File > Open Example Calculations..., General Chemistry, OK. Select h2o_dimer (Examples > Intermolecular interactions) and open the Viewer; then open the Basis Set Tool on the same calculation and close its tab with × without changing anything. The Viewer's tab says Viewer, not Builder; closing the Basis Set Tool asks nothing. #1088 3d73eede3
Folder icons under SSH and server roots Edit > Preferences > Data: add an SSH folder (any host you can log in to) and, if you have one, an ECCE server. Under each root make a new folder and in it a new calculation (copying in from Local data fails, #1104). Folders under the SSH root are green, folders under the ECCE server maroon; no row has a coloured background; the calculation keeps its own code icon. #767 ad97799a7
Import an output file by right-click In the Organizer, open a folder that holds an ORCA or Gaussian output (an SSH folder if you have one, else a local folder). Right-click the output file > Import as Calculation..., pick a project. The item appears only on output files; the new calculation has the energy and geometry, and its annotation says where the file came from #1092 b21181c03
MD speed summary Open an MD calculation with a speed distribution (Examples > Gases, liquids and solids, ar-gas-300K), MD analysis > speeds. The summary line reads "mean speed … m/s (Maxwell–Boltzmann …), rms …, most probable vₚ … m/s" and the plot's line is labelled vₚ #1093 02b864a04
Cut Cluster File > Open Example Calculations..., pick a crystal (or File > Import a quartz CIF). Select one Si, Build > Cut Cluster..., radius 5 Å, caps H, OK; then Edit > Undo. A non-periodic SiO₂ cluster with H on the cut O atoms, no two H atoms close together; Undo brings back the crystal #1033 73ce8636a
Properties list stays on top File > Open Example Calculations..., General Chemistry, OK. In Examples > Intermolecular interactions open h2o_dimer in the Viewer, click Density Map in the Properties list. Drag its caption out to float it, then drag it back onto the top edge of the Properties list; float it again and use Dock. Each time the Density Map docks under the Properties list and stays visible; the list stays at the top of the column #1073 f75ed29da
QE pseudopotential directory per machine Machines > Register Machines, pick a machine with Quantum ESPRESSO, Codes tab: enter a folder in Pseudopotential directory that lacks one UPF file, Save. New Calculation with Quantum ESPRESSO on Si from the Structure Library, launch on that machine. A warning before launch names the missing UPF file; Launch anyway still submits, and the input on the machine has that folder as pseudo_dir #989 915ac645a
Density Map at small screens Set the screen (or a VM) to 1024×768. File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer, click Density Map (docked). Zoom with the wheel, then open Options and move Offset; click Reset. Options and Reset are on the MO row; with Options closed there is no Offset row and the map is about 200 px high; with Options open the panel scrolls; Reset is greyed until you zoom or move the offset and then restores the whole plane at offset 0 #1081 5c11d8226
Density Profile under Options File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer and click Density Profile in the Properties list. Then click Options. Closed: only the mode, From/to, Options, the orbital list and the plot. Open: quantity, orbital set, y axis and Show all are there, and changing them redraws the plot as before #1074 20e49509e
Density Map Fill File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer, click Density Map, open Options and tick Fill; pick an occupied orbital, then the total density. Close and reopen the Builder. Orbital: one sign blue, the other orange, white at the node and outside the outermost line; density: viridis colours; the key has a colour bar; Fill is still ticked after reopening; Export .png gives the same picture #1077 80af601a7
OPDOS groups, Options, window File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer, click Density of States (OPDOS). Type 2-6 in B; select atoms 4-6 in the viewer and click A's Use selection. Open Options, then click Open in window... and change Width. A becomes 4-6 and B 2-3 with a note, no refusal; closed, only A, B, Options, Open in window... and the plots show; the window has both plots, follows the Width change and exports its own PNG #1078 e0fdb18ad
Properties list groups File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer and look at the Properties list; then open a Quantum ESPRESSO crystal from Molecular and covalent solids. Vibrational Frequencies under Vibrational spectra; Diffraction under Diffraction and scattering, not under Geometry; no group named Vibrations, Excited states or Magnetic properties #1079 07eb8edfe
One program: tools as tabs Start with ECCE_ONE_PROCESS=1 ecce. File > Open Example Calculations..., General Chemistry, OK. Select h2o_dimer (Examples > Intermolecular interactions) and open it in the Viewer, then in the Calculation Editor; from the editor open the Basis Set Tool. Use Open in Window on one tab, then Move to Tabs. Quit. Each tool opens as a tab in the Organizer window with its own menus; switching tabs swaps the menu bar; Open in Window and Move to Tabs keep the same tool; Quit asks once about unsaved changes and ends cleanly. Without ECCE_ONE_PROCESS every tool opens in its own window as before #1061 064453313
Feedback when a tool starts File > Open Example Calculations..., General Chemistry, OK. Select h2o_dimer (Examples > Intermolecular interactions) and click the Viewer button; click it again at once. At once a busy cursor and "Opening the Viewer for h2o_dimer…" in the status line; if the Viewer takes longer than about 1.5 s a small "Starting the Viewer…" window; all of it goes when the Viewer is up; only one Viewer opens #1071 1a6dcd48a
Turned view lit from the front File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer. Turn it with the mouse by about 90° about the horizontal axis, then File > Save Image... at 2x. The saved picture is lit like the screen, from the front; atoms are not dark #1075 b7cb47454
Smooth orbital surface in saved images File > Open Example Calculations..., General Chemistry, OK. Open h2o_dimer (Examples > Intermolecular interactions) in the Viewer, show an occupied orbital as a surface in MOs, then File > Save Image... at 4x. A progress bar may show briefly; the saved lobes have smooth outlines, not straight facets; the surface on screen is unchanged afterwards #1075 4d82eddf1
ELF and LOL surfaces closed File > Open Example Calculations..., General Chemistry, OK. In Examples > Intermolecular interactions open h2o_dimer in the Viewer, Properties > Orbitals > Surfaces: choose LOL at isovalue 0.50, then ELF at 0.80. Smooth closed surfaces around the O–H bonds and the oxygens, no torn sheets or holes; density and NCI look as before #1076 1a1ffc2d1
Save Image (print quality) File > Open Example Calculations..., Example set Getting Started, OK. Open benzene (ORCA) in the Viewer, Properties > MOs, select the HOMO and compute its surface. File > Save Image...: 2x, white background Yes, save; then again at 4x. The PNG is 2x (then 4x) the view size; orbital lobes smooth and see-through (no dotted pattern), edges smooth, bonds and labels as thick relative to the picture as on screen; no 'Mode: Select' or atom-count text; three dialogs in a row are acceptable or should become one (say which) #1059 f00a3d432
New calculations in another code Open the General Chemistry examples. In the project table of Examples > Atoms, select He, Be and Ne (Ctrl-click; closed shells, so one setup fits all three), then Tools > New Calculations in Another Code...; choose ORCA, OK. In the Calculation Editor that opens, set DFT, B3LYP, def2-SVP, Energy, and save. Click Make the Others in the small window. Three new calculations He_orca, Be_orca, Ne_orca, all Ready with the same setup and each with its own atom; the message line says 2 more were made; the item is not in the tree's right-click menu or the Edit menu #1037 05b0770c2
Properties list with a large pane Open the General Chemistry examples; in Examples > General_Chemistry > Diffraction open nacl_powder in the Viewer and choose Properties > Diffraction. The Properties list still shows about eight rows above the docked Diffraction pane, and you can click any of them; layout usable at your screen size #1022 97756c08f
Basis Set Tool size Open any calculation in the Calculation Editor (e.g. an ECCE-QM example), click the Basis Set button; close it, resize the Basis Set Tool, close and open it again. It opens no bigger than its content and fits on your screen, periodic table fully readable, the selections list grows with more rows; the size you set comes back #1029 5b6fbfa5e
Stress tensor view File > Open Example Calculations..., Example set General Chemistry, OK. In Examples > General_Chemistry > Diffraction open nacl_powder in the Viewer, Properties > Geometry > Stress Tensor; untick and tick Show in viewer. The table, then pressure, von Mises, principal stresses and a plain sentence on how the cell wants to change; blue (tension) or vermillion (compression) arrows on the cell, and none when unticked; panel layout readable at your screen size (arrows now outside the cell, labels at their tips: #1021) #1015, #1021 eec984b76
Diffraction pane File > Open Example Calculations..., Example set General Chemistry, OK. In Examples > General_Chemistry > Diffraction open nacl_powder in the Viewer, Properties > Diffraction. Change the source to Mo, then View > Single crystal; hover a spot; click Options... and change the film distance; click Pattern, then Pattern again. The pattern appears in the pane without a Calculate button and redraws by itself after each change ("Calculating..." in the line under it); hovering shows hkl, d, |F| and whether the reflection is extinct; Pattern opens the same pattern in a window and closes it again; layouts usable at your screen size #1013 0723a2c3c
Selecting several calculations File > Open Example Calculations..., Example set Getting Started, OK. In Examples > Getting_Started: click benzene, Shift+click water (the ECCE-QM one), then Ctrl+click ethanol; right-click one of the selected rows. Then File > Open Example Calculations..., Example set Workflows, OK. In Examples > Workflows > SN2_Cl-_and_CH3Br do the same with reactant, qst3 and product. Shift+click selects the range, Ctrl+click toggles one row, right-click keeps the selection and its menu offers Compare Energies... and Make Workflow from Selected... #925 dev-1e2de2058
Reaction overview table File > Open Example Calculations..., Example set Workflows, OK. In Examples > Workflows > SN2_Cl-_and_CH3Br click the first calculation, Shift+click the last, right-click > Compare Energies..., then Reaction overview.... Column headers carry their units (ΔG / kJ mol⁻¹, k (TST) / s⁻¹); the note under the table explains Spread in words; nothing cut off at the left edge. #900 dev-ef0a2e30f
Match bands 1. File > Open Example Calculations..., Example set Spectroscopy, OK.
2. Examples > Spectroscopy > Sulfate_coordination: open sulfate in the Viewer, Properties > Vibrational Frequencies, Open in window....
3. Compare... (Other spectra group), choose co_nh3_5_oso3 (match modes).
No question about atoms. A window with a Common atoms line (S1 O2 ... = S.. O..) and fit RMSD, then a table of paired bands with Shift and Overlap; no S–O band paired with one above 1500 cm⁻¹; the window is not wider than the screen and the note wraps. #803 dev-1e2de2058
Reaction overview chart File > Open Example Calculations..., Example set Workflows, OK. In Examples > Workflows > SN2_Cl-_and_CH3Br click the first calculation, Shift+click the last, right-click > Compare Energies..., Reaction overview.... Make the window smaller than its content. The energy-profile chart and the 'Energy profile of' list have a usable height; the result text scrolls and can be selected and copied (Ctrl+C). #899 dev-ef0a2e30f
Selecting in a workflow File > Open Example Calculations..., Example set Workflows, OK. Click Examples > Workflows > SN2_Cl-_and_CH3Br: the boxes and, below them, the workflow's table.
1. In the table: click a row, Ctrl+click a second, Ctrl+click a third, Ctrl+click the second again; then click the first and Shift+click the last.
2. In the boxes: click sn2_reactant, Ctrl+click sn2_product; then Tools > Energy Calculator....
1: each click selects the row clicked; Ctrl adds or removes that row; Shift selects the range.
2: the two boxes are marked and the same two rows are selected in the table; Energy Calculator opens with sn2_reactant and sn2_product. There is no 'Back to Table' button; clicking Workflows in the tree leaves the workflow.
#951, #931 dev-ef0a2e30f
Auto-run starts with the button File > Open Example Calculations..., Example set Getting Started, OK. Right-click Examples > Getting_Started > water (ECCE-QM) > Apply Recipe..., choose xTB first, then conformers, Create.
1. Watch whether any Calculation Editor opens.
2. Tick Run the remaining steps automatically.
3. Click another folder in the tree, then the workflow again.
4. Press Launch Ready Steps (set the machine to this computer in the Launcher if it asks).
1: no editor opens by itself.
2 and 3: nothing is launched.
4: the xTB step launches; when it is Complete, the CREST step becomes Ready and launches by itself.
#926 dev-ef0a2e30f
The workflow that crashed the Organizer Double-click the workflow that crashed the Organizer on 2026-11-10 (auto-run ticked, made from a recipe before 2026-11-08). The workflow opens; nothing is launched; its xTB and CREST boxes show a state (Ready, or Created with 'no theory yet') instead of a crash. #950 dev-ef0a2e30f
MLP (MACE): relax a crystal 1. Organizer: select a project, File > New > MLP (MACE) Calculation..., name it nacl_mace.
2. Builder: File > Add Structure from File..., Local Filesystem, /opt/ecce/data/client/examples/test/ (or build any small periodic cell); save and quit.
3. Editor: Model MACE-MP-0 medium-mpa-0, Runtype Geometry, in Runtype Details... tick Relax the cell. Save.
4. Launch..., machine niobium, 4 processors.
The Notes line says the energies are for screening, not for reporting. The run finishes in under a minute and the Progress box shows one line per optimiser step. Properties > Geometry Trace plots the energy and the Calculation Summary names the model and its version. #728 dev-2a649a02d
MLP (MACE): screen sites in a host 1. Organizer: right-click the finished nacl_mace > New from This > Screen Sites with MLP....
2. In the dialog: Mode One ion per void, Element Li, leave the three distances at their defaults. Create.
3. A folder nacl_mace sites appears with the host and one calculation per site. Select all of them, Launch Selected, machine niobium.
4. When they are Complete: right-click the folder > Site Screening Results, then open the results calculation in the Viewer.
The dialog lists the symmetry-distinct sites before creating. After the runs, Properties > Geometry > Sites shows a table ranked by E − E(host) (eV) with each site's neighbours, a structure picture per row, and New Calculation from Selected... to send the best sites to CP2K or Quantum ESPRESSO. #728 dev-2a649a02d
Vina: dock a ligand in a receptor 1. Fetch a structure that already holds a protein and its bound ligand (for example PDB entry 1IEP) and save the .pdb file.
2. Organizer: File > New > Vina Docking Calculation..., name it imatinib_dock.
3. Builder: File > Add Structure from File..., choose that .pdb. The whole system appears. Save.
4. Select the atoms of the small molecule (Edit > Select Molecule on one of its atoms), then Tools > Docking Box Around Selection. A green box is drawn round them.
5. Editor: in Runtype Details... check that Ligand atoms holds those atom numbers and that the box numbers match; set Exhaustiveness 8. Save.
6. Launch..., machine niobium.
The green box is drawn in the viewer and follows the numbers in Runtype Details. The run takes a few minutes. Properties > Geometry > Poses lists the poses with Vina score (kcal mol⁻¹), best first, no population column. Clicking a row shows that pose; with Pocket view ticked the viewer frames the pocket, drawing the nearby residues as sticks with their bonds and the small molecule as balls and sticks. #455 dev-2a649a02d
Gaussian 16: orbitals of a scan point 1. Organizer: File > Open Example Calculations..., Example set Computational, OK.
2. Right-click Examples > Computational > H2_dissociation_with_RHF,_UHF_and_CCSD > h2_rhf_scan > New from This; in the Editor switch the code to G16, keep Runtype Geometry, Save and Launch... on niobium.
3. When Complete: Viewer > Properties > Relaxed Scan, click a point in the middle of the curve, then open MOs.
The MOs panel shows the orbitals of the point selected, and its note names that point rather than the last one. #549 dev-2a649a02d
ECCE-QM: faster DFT frequencies 1. Organizer: new ECCE-QM calculation, build water or ammonia in the Builder.
2. Editor: Theory DFT, functional B3LYP, basis 6-31G*, Runtype GeoVib. Save, Launch... on niobium with 4 processors.
3. Repeat with Solvation set to water (CPCM) in Theory Details.
Both finish; the Progress box's frequency stage says analytic and the finished line shows no leftover pass= or phase= fields. Properties > Vibrational Frequencies lists the modes with IR intensities; the water bend moves down by about 50 cm⁻¹ with the solvent. #394 dev-2a649a02d

Linux, on main

Check How to test What to look for Issue In build
Carbon monoxide gets a triple bond Builder, new structure: build CO (a carbon and an oxygen, nothing else), then Build > Clean. Also open an example with a nitrile or N2 and Clean it. CO is drawn with a triple bond and nothing is flagged unresolved; the bond note says it uses a lone pair (C1-/O2+). N2 and nitriles are unchanged. A methyl radical is still flagged. #1292 a5cd1336f
Docking box warning for a ligand of your own The imatinib Vina calculation (1IEP) from the row "Vina: dock a ligand in a receptor". In its Builder, File > Add Structure from File... and pick any small molecule (a .xyz or .frag you drew). Leave the search box automatic. Save, then Launch. Before launching, a warning says the search box holds very few receptor atoms and is not on a binding site, names the count, and points at Tools > Docking Box Around Selection. The buttons are Cancel and Launch anyway; Launch anyway works. Without the added molecule (the ligand from the crystal file), there is no warning. #1296 f77cfaaf7
Window close button asks before quitting Organizer on the benzene example: open a Builder as a tab and select it, then click the window's X in the title bar. Repeat with the Organizer tab selected, and once with File > Quit. Run ecce from a terminal so its output is visible. Every route asks before quitting, with whatever tab is selected, and Cancel leaves the window open. The terminal prints one ECCE close: line per attempt. If it ever quits without asking, copy those lines into the issue - they name which of the three conditions caused it, which is the whole point of this check. #1291 e21db5468
Reaction overview details Organizer: File > Open Example Calculations..., Workflows, SN2 Cl- and CH3Br, OK. Click the SN2 folder, select all its calculations in the table (click the first, Shift+click the last), right-click > Compare Energies...; in that window press Reaction overview...; at the top change G treatment:; press Details Details shows a heading per reaction, soft-mode and tunnelling tables, the treatment in words, and References (Eyring, Wigner, Eckart and the treatment's paper) #900 dev-ef0a2e30f
Reaction overview: picked reactions As above up to Reaction overview...; then press Add Reaction... and tick 2 × a reactant and a product The SN2 reaction is filled in without typing; the TS list greys calculations without exactly one imaginary frequency; an unbalanced choice keeps OK disabled with "Not balanced: left ..., right ..."; results table above the chart #900 dev-ef0a2e30f
Step without launch settings 1. File > Open Example Calculations..., Example set Getting Started, OK.
2. Right-click Examples > Getting_Started > water (ECCE-QM) > Apply Recipe..., choose Conformers, press Create. A workflow opens: the water box (Complete), then the recipe's boxes.
3. Do not open any Launcher. Press ▶ on the first box after water.
4. Close the Launcher window without launching.
5. Press Launch Ready Steps.
3: a Launcher window opens for that box's calculation (its name in the title); the box is not skipped and no message 'no machine stored' appears.
4: nothing is launched; the box stays Ready.
5: the Launcher opens again for the same box.
#901 760194787
CREST protomers File > Open Example Calculations..., Workflows, Aminopyridine protonation. Select the CREST calculation (crest-ap_protonation), Viewer, Properties > Protonation Sites; pick each protomer; then Edit > Undo Each protomer shows the added proton; energies relative to the lowest #912 blocked by #954 (CREST calculation missing from the example)
Organizer follows changes File > Open Example Calculations..., Example set Getting Started, OK. 1. Click Examples > Getting_Started; in a terminal: cp -r ~/.ECCE-local/users/local/Examples/Getting_Started/water ~/.ECCE-local/users/local/Examples/Getting_Started/water_copy.
2. Select benzene in the table, then cp -r ~/.ECCE-local/users/local/Examples/Getting_Started/ethanol ~/.ECCE-local/users/local/Examples/Getting_Started/ethanol_copy.
3. rm -r both copies.
1: the copy appears in the tree and table within a few seconds, no Refresh needed.
2: the selected row stays selected and the table keeps its scroll position.
3: the copies disappear by themselves.
4: nothing changes while the dialog is open; the copy appears after it closes.
#889 845af8614
Series from structures 1. File > Open Example Calculations..., Example set Test, OK (gives Examples > Test > Series_from_structures > series_template).
2. In a terminal (New Series is command-line only since #805):
ecce-series ~/.ECCE-local/users/local/Examples/Test/Series_from_structures/series_template ~/.ECCE-local/users/local/Examples/Test/Series_from_structures /opt/ecce/data/client/examples/test/series-from-structures/structures/*.xyz
3. In the Organizer, select the Series_from_structures folder and refresh it if they do not appear by themselves (Refresh button on the toolbar).
4. Open the new ammonia calculation in the Calculation Editor.
2: one line per structure, "water: made ...", "ammonia: made ...", "methane: made ...".
3: three new calculations next to series_template, state Ready.
4: ORCA, B3LYP-D3BJ, def2-SVP as in the template; N and 3 H, charge 0, multiplicity 1; an input file generated. Run Mgmt > Launch Selected is offered.
#621, #915 dev-c2e64287a
Bands and spectra 1. File > Open Example Calculations..., Example set Spectroscopy, OK; then the same with Test (for the spectrum file).
2. Examples > Spectroscopy > Sulfate_coordination: open sulfate in the Viewer, Properties > Vibrational Frequencies.
3. Open in window..., then Compare... (Other spectra group), choose co_nh3_5_oso3 (match modes) (nothing is asked; the atoms are matched by themselves).
4. In the same window, Compare... again, choose co_nh3_5_oso3 (the entry without "match modes"), tick Difference.
5. Experimental..., choose /opt/ecce/data/client/examples/test/spectra/sulfate_test_spectrum.csv.
6. Change the frequency scale factor; then Export .csv...
3: a table of paired bands with frequencies, overlaps and shifts (B minus A); the free sulfate S–O bands (about 1127 and 596 cm⁻¹) split in the complex; clicking a row selects its mode.
4: a pane below the spectra with B minus A around zero, same axis and zoom.
5: a dashed curve (absorbance) with bands near 1105, 1050, 983, 618 and 450 cm⁻¹, scaled to the computed maximum. The file is synthetic test data, not a measured spectrum.
6: only the computed curves move; the exported CSV has the experimental column.
#707, #915 dev-c2e64287a
Start with the cluster unreachable The jobs: Duplicates of Examples > Spectroscopy > Sugars > alpha_d_glucopyranose (ORCA) launched on Kebnekaise. With calculations running or waiting on a password-login cluster (Kebnekaise), disconnect the VPN, then start ecce The Organizer stays open; at most one password window for that cluster; stderr may say 'could not open the ssh connection ... no answer in time', with no 'trying the built-in client' line; the jobs show waiting for login. After reconnecting the VPN, one Run Mgmt > Reconnect brings the monitors back #780 9ae7218f
MOs of a scan step (ORCA) File > Open Example Calculations..., Example set Computational, OK. Open Examples > Computational > H2_dissociation_with_RHF,_UHF_and_CCSD > h2_rhf_scan (ORCA) in the Viewer; Properties > Relaxed Scan: click a point near the minimum, then one at a long distance; each time open Properties > Orbitals > MOs and draw the HOMO. The MOs panel says which scan point it shows, and the orbitals change with the selected point (bonding orbital spread over both H at short distance). #549 dev-1e2de2058
Density Profile: electrons per length File > Open Example Calculations..., Example set Organic Chemistry, OK. Open Examples > Organic_Chemistry > Bonding_in_hydrocarbons > ethene (ECCE-QM) in the Viewer, Properties > Density Profile, Along a line from C1 to C2, quantity Electrons per length (plane integral), Selected orbitals: the π orbital (HOMO); then set within radius to 0.5. Also with the side pane narrow. The π curve is not zero between the carbons (unlike its density on the axis); the area printed under the plot is about 1; with radius 0.5 it is smaller; the radius control fits in a narrow pane. #749 dev-1e2de2058
Gaussian 16 final orbitals without the checkpoint File > Open Example Calculations..., Example set Workflows, OK. Right-click Examples > Workflows > SN2_Cl-_and_CH3Br > reactant (Gaussian 16, shipped without its .chk) > Duplicate with Final Orbitals; open the copy in the Calculation Editor and read the orbital-guess line; Final Edit; launch it on this machine. Also: Preferences > Data, look at the new Stored results box (leave it off). The guess line ends 'from its results.h5'; the input has Guess=Cards and an @guess.cardsin line; the job's SCF takes only a few cycles and ends at the reactant's energy. The Preferences switch is off. #690 dev-1e2de2058
Viewer tab does not dirty a Builder File > Open Example Calculations..., Example set Organic Chemistry, OK. Open Examples > Organic_Chemistry > Reactions > diels_alder_ts (ORCA) in the Builder and touch nothing. Open two other finished calculations in Viewer tabs. Close the Builder tab. The Builder closes with no save question. Then make one real edit in the Builder (add an atom), open another Viewer tab, and close the Builder: it does ask. #1307 6b3e68a79
Generate Bonds after a save asks on close In the Builder, build any fragment with open valences (nubs), File > Save, then Build > Generate Bonds so the nubs disappear. Close the Builder tab without saving again. It asks whether to save. Before the fix it closed silently and the deleted nubs were lost. Present in every released version of ECCE, so it is worth checking the 9.4.x backport the same way. #1308 6b3e68a79
Dragging in the Organizer tree Start ecce from a terminal. File > Open Example Calculations..., Example set Getting Started, OK. In the tree, drag Examples > Getting_Started > water onto another folder (make one with File > New > Project... if you have none); then drag a whole folder onto another folder. The calculation and the folder move to where they were dropped and the tree shows them there. The terminal stays quiet: no gtk_drag_begin warning. #983 cfb132c9f
Servers menu pops under its button Organizer: click the Servers button on the toolbar. The menu opens directly under the Servers button and its entries can be chosen. Before the fix it appeared in a corner of the screen or not at all. #983 bdd566685
A Builder in a window comes back where it was left File > Open Example Calculations..., Example set Getting Started, OK. Open Examples > Getting_Started > water in the Builder, right-click its tab > Open in Window. Move that window and change its size, then quit ECCE. Start ecce again and open the same Builder in a window. It comes back at the size and place it was left. The first reopen after upgrading can still be wrong, because the saved file still holds the bad size and position written by earlier builds; what counts is that the second quit-and-reopen is right. #983 bdd566685
Builder measurement prompt appears over the measurement File > Open Example Calculations..., Example set Getting Started, OK. Open Examples > Getting_Started > water in the Builder, measure a distance between two atoms (and an angle over three), then double-click the measurement label in the 3-D view. The box for typing a new value appears over the measurement that was double-clicked, not in another part of the screen or off the screen edge. #983 bdd566685
Details dialog opens over the editor File > Open Example Calculations..., Example set General Chemistry, OK. Duplicate Examples > General_Chemistry > Diffraction > nacl_powder (Quantum ESPRESSO) and open the copy in the Calculation Editor; press Theory Details..., close it, then Runtype Details.... Quantum ESPRESSO, NWChem, CP2K, CREST, GROMACS and MACE open these in a window of their own; ECCE-QM, ORCA, Gaussian 16, MOPAC, xTB and Vina fill the panel instead and are not this check. Each window appears over the ECCE window, roughly centred on it, and is fully on screen. #983 bdd566685
An MD tool in a window comes back where it was left File > Open Example Calculations..., Example set General Chemistry, OK. Open Examples > General_Chemistry > Gases,_liquids_and_solids > ar-gas-300K (GROMACS) and open its MD Dynamics tool; right-click its tab > Open in Window, move the window and change its size, close it and open it again. Repeat with MD Energy, MD Optimize, Gmx Prepare and MD Prepare if you have a calculation that offers them. The tool reopens at the size and place it was left, not at the size of the main window. #983 bdd566685
Docking poses open at once and their labels can be read The imatinib_dock Vina calculation (1IEP) from the row "Vina: dock a ligand in a receptor", after its run has finished. Open it in the Viewer and choose Properties > Geometry > Poses; tick Pocket view and click a few pose rows. The poses appear within a second or two, not after minutes of a frozen window. The residue names drawn round the pocket can be read against the background (they used to be white on white); they follow the Foreground colour in Preferences. #1293 40c93bb62

Windows

None waiting.

macOS

None waiting.

Clone this wiki locally