You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
IBM: default no-slip ghost is first order; inner-wall shear error is 20-30% at 20-30 cells per radius unless ib_wall_order = 2 #2389
For the rotating-cylinder Couette setup, the inner-wall shear error (rms, against the exact profile) with the default ghost value stays 20 to 29% at 20 and 30 cells per radius, even after the wall-point velocity fix (#2383): 0.214 / 0.292 (Mach 0.01, Re 11) and 0.204 / 0.277 (Mach 0.05, Re 40). With ib_wall_order = 2 it is 0.015 / 0.013 and 0.034 / 0.026, and with TSC plus the compact viscous gradient about 0.0065 / 0.0019. The static outer wall is also first order by default: the ghost value is the wall velocity itself, where a mirror through the wall is second order.
Question
Should ib_wall_order = 2 (and possibly ib_ip_interp = 2) become the default for no-slip walls? That changes the goldens of every IB test with a wall and needs verification on several geometries, so it needs a decision before a PR. At minimum the docs should say which options give second-order wall accuracy.
Evidence
Numbers from the validation work for the annulus and Couette examples (#2375, #2383). A torque error of 2.6% on master drops to 0.06% with the wall-point velocity fix plus ib_wall_order = 2.
Activity
sbryngelson commentedon Nov 22, 2026
Related pull requests: #2176 (
ib_wall_order = 2, merged), #2165 (TSC interpolation, merged), #2383 (wall-point velocity, open), #2375 (conduction annulus, merged), #2373 (wall-order Couette validation, open).AI-assisted (Claude Code).