You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
IBM wall column: Intel ifx release lane differs from the other lanes by 1.5e-4 on DF9526DB (time-step sequence), cause unknown #2400
The sub-grid wall conduction column test DF9526DB (2D -> Chemistry -> IBM -> Reacting Surface -> Wall Column -> Time-Step Limit, 149 smooth steps limited by the wall-column time step) failed only on the Intel ifx release CPU lane (max abs 1.54e-4 at one variable, 7.7e-4 relative at a near-zero entry); GNU, macOS, Intel reldebug, NVHPC CPU and GPU lanes, and an A100 pass. It was not a round-off effect (a 1e-12 relative nudge to the freestream velocity changes the output by less than 1e-7); the end state depends on the step sequence to first order (a 0.1% change in wall_column_dt_frac moves a momentum entry by 1.6e-3), and the Intel gap corresponds to a step sequence about 1e-4 relative different. override_tol is 1e-3 (#2329) as a stopgap; why Intel's f_wall_column_dt sequence differs is not found. A temporary print of the dt history on an Intel CI lane would show where it diverges.
Activity
sbryngelson commentedon Nov 22, 2026
Related pull requests: #2329 (wall conduction column, merged;
override_tolstopgap).AI-assisted (Claude Code).