2 changes: 2 additions & 0 deletions docs/documentation/validation.md
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,8 @@ Every check has an example in `examples/` with a checker script and a README, an
Status words: **validated** (agrees with the reference within the stated error), **partially validated** (agrees where measured; a regime or quantity is open), **open discrepancy** (disagrees, cause known or not), **comparison only** (reference data are qualitative).
Errors are (MFC − reference)/reference.

Separate pages: @ref validation_wall_order_couette "Wall-normal ghost velocity at viscous walls" (`ib_wall_order` against plane Poiseuille and Taylor-Couette flow).

## Moving-body kinematics {#sec-validation-moving-kinematics}

**Status:** validated. **Code:** `master` at 067f23074, with the stage-consistent position update of [#2040](https://github.com/MFlowCode/MFC/pull/2040). **Examples:** `examples/2D_mibm_constant_acceleration`, `examples/3D_mibm_wall_collision`.
Expand Down
115 changes: 115 additions & 0 deletions docs/documentation/validation_wall_order_couette.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,115 @@
@page validation_wall_order_couette Wall-Normal Ghost Velocity at Viscous Walls

# Wall-Normal Ghost Velocity at Viscous Walls

**Status:** partially validated (the gain of `ib_wall_order = 2` is measured on a flat and a curved wall; two limits are not explained).
**Code:** `master` at dd9778b26 (contains #2176 `ib_wall_order`, #2169 centripetal ghost pressure, #2165 TSC image points, #2212 compact viscous gradients), unmodified. NVIDIA A100, NVHPC 25.11, OpenACC, double precision, one rank.
**Last run:** 2026-11-21. **Examples:** `examples/2D_ibm_plane_poiseuille`, `examples/2D_ibm_taylor_couette`.

#2176 added `ib_wall_order = 2`, a two-probe quadratic wall-normal ghost velocity at no-slip walls, and reported no accuracy gain against an exact solution. This page measures it against two exact viscous solutions, for `ib_wall_order` 1 (the default mirror) and 2, and records what happens at a rotating curved wall.

## Setup

| Item | Channel (flat wall) | Annulus (curved wall) |
| :--- | :--- | :--- |
| Geometry | two static rectangle walls at y = 0 and y = H = 1, periodic in x | inner circle R = 1 (rotating, `moving_ibm = 1`), outer wall an STL ring at r = 2R (fixed); both no slip |
| Gas | rho = 1, sound speed 1, constant mu, 1 fluid | same |
| Drive, regime | body acceleration, peak Mach 0.05, Re = u_max H / nu = 1 | tip Mach 0.05, Re = Omega R^2 / nu = 10 |
| Run | from rest, 12 slowest viscous times, fixed dt at acoustic CFL 0.3 | same |
| Grids | 8, 16, 32 cells across the gap; wall on a cell face or 0.37 cell inside it (8, 16) | 10, 20, 40 cells per R, grid centred on the body |
| Numerics | WENO5, HLLC, SSP-RK3, `fd_order = 4`, `weno_Re_flux = T`, `ib_wall_order` 1 or 2 | same |

## Reference data

1. Channel: \f$u = g y (H-y)/(2\nu)\f$, \f$u_\text{max} = g H^2/(8\nu)\f$, flow rate \f$g H^3/(12\nu)\f$, wall shear \f$\rho g H/2\f$.
2. Annulus (incompressible): \f$u_\theta = A r + B/r\f$ with \f$A = -\Omega R^2/(r_2^2-R^2)\f$, \f$B = \Omega R^2 r_2^2/(r_2^2-R^2)\f$; torque on the inner body per unit depth \f$-4\pi\mu B\f$ (the outer wall receives \f$+4\pi\mu B\f$).
3. Compressibility (O(M^2)), viscous heating and the density drift of the immersed boundary are not in the references. The mean density rises over the run (about 2 % at 10 and 0.4 % at 40 cells per R in an earlier measurement, not repeated here).

## Quantities

- **Velocity error (L2):** rms over the fluid cells (centre inside the gas and more than half a cell from a wall in the annulus), divided by u_max (channel) or Omega R (annulus). In the annulus it is split into the azimuthal-mean part (error averaged in bins of one cell width in r) and the rest.
- **Flow rate (channel):** sum of u dy over the fluid cells against the exact value.
- **Torque (annulus):** from the face fluxes between each body and the fluid (`ib_state_wrt`, `ib_force_wrt`), mean over the last 10 % of the run, relative to the exact value.
- **Wall speed:** cubic fit (annulus) or quadratic fit through the three nearest cells (channel) extrapolated to the wall; exact value Omega R (annulus) or 0 (channel).
- **Wall force (channel):** from the face fluxes against g H Lx / 2 per wall. In steady state this is the body-force balance, so it cannot separate the two orders.

The scripts are `check_poiseuille.py` and `check_couette.py`; the text output labels each cell with its right face, so cell centres are the labels minus dx/2.

## Results

### Flat channel, Mach 0.05

Wall on a cell face (offset 0) and 0.37 cell inside it. Errors are signed (MFC minus exact over exact) for the flow rate.

| Cells across | Offset | L2, order 1 | L2, order 2 | Flow rate, order 1 | Flow rate, order 2 |
| ---: | ---: | ---: | ---: | ---: | ---: |
| 8 | 0 | 0.455 | 0.0545 | +0.682 | +0.0866 |
| 8 | 0.37 | 0.474 | 0.0724 | +0.679 | +0.0872 |
| 16 | 0 | 0.216 | 0.0185 | +0.322 | +0.0279 |
| 16 | 0.37 | 0.223 | 0.0204 | +0.320 | +0.0250 |
| 32 | 0 | 0.113 | 0.00668 | +0.159 | +0.00971 |

- Order 1 behaves as if the no-slip sat about 0.75 cell outside the wall (flow rate 1.7 times the exact one at 8 cells across). Order 2 reduces the velocity error by 8 to 17 times from 8 to 32 cells and converges at about 1.5 orders (L2 0.0545, 0.0185, 0.00668).
- Wall velocity from the quadratic fit, in units of u_max (exact 0): order 1 0.77, 0.42, 0.46 at 8, 16, 32 cells; order 2 0.115, 0.051, 0.020.
- The wall force agrees with g H / 2 within 1.2e-3 for both orders when the wall is on a cell face. With the wall inside a cell the order 2 force splits unequally between the two walls (+-7 % at 8 cells, +-4 % at 16), because the fluxes are taken at the staircase faces, not at the wall.

### Taylor-Couette annulus, Mach 0.05

| Cells per R | Order | L2 / Omega R | Azimuthal mean | Rest | Inner torque | Outer torque | Wall speed (fit) |
| ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: |
| 10 | 1 | 1.66e-2 | 5.3e-3 | 1.60e-2 | -3.0e-3 | -1.48e-2 | -5.4e-2 |
| 10 | 2 | 1.23e-2 | 5.2e-3 | 1.14e-2 | -1.7e-3 | -9.7e-3 | -3.9e-2 |
| 20 | 1 | 1.09e-2 | 8.3e-3 | 8.5e-3 | -1.19e-2 | -1.87e-2 | -6.3e-2 |
| 20 | 2 | 6.5e-3 | 4.2e-3 | 5.6e-3 | -3.7e-3 | -5.8e-3 | -3.8e-2 |
| 40 | 1 | 8.1e-3 | 8.5e-3 | 3.8e-3 | -1.63e-2 | -1.94e-2 | -7.2e-2 |
| 40 | 2 | 4.7e-3 | 4.9e-3 | 2.0e-3 | -6.6e-3 | -8.8e-3 | -3.4e-2 |

- The velocity error is 26 to 42 % lower with order 2 at every resolution. Both converge at only about 0.4 to 0.5 order between 20 and 40 cells per R (order 1 1.09e-2 to 8.1e-3, order 2 6.5e-3 to 4.7e-3).
- The azimuthal-mean part does not converge for either order (order 1: 5.3e-3, 8.3e-3, 8.5e-3; order 2: 5.2e-3, 4.2e-3, 4.9e-3). It is a deficit of angular velocity near the inner wall: the fitted wall speed is 5 to 7 % low for order 1 and 3 to 4 % low for order 2, with no trend with resolution.
- The torque from the face fluxes is within 2 % of the exact value for both orders, with order 2 about 2 to 3 times closer at 20 and 40 cells per R. It does not converge monotonically, and the inner and outer torque differ by up to 1.2e-2, so the run is not exactly steady or the angular momentum is not exactly conserved.
- The change of the azimuthal velocity over the last save interval is below 1.3e-5 of Omega R in these runs.

### Rotating inner wall with the optional wall treatments, Mach 0.01

These numbers were measured on `master` with the ghost-velocity defect described below (the rotating body's wall velocity is evaluated at the ghost point, not at the wall point). They are not the expected accuracy of a rotating wall. Same annulus at tip Mach 0.01 and Re = 11, run for 4 slowest viscous times, `ib_wall_order = 1` unless noted. The centripetal ghost pressure of #2169 is always on for a spinning body; `ib_ip_interp = 2` (TSC) and `ib_visc_compact = T` (compact viscous gradients next to a body) are opt-in. Shear is the inner-wall shear \f$S = r\,d(u_\theta/r)/dr\f$ from local cubic fits at 96 wall points (3.5 to 5 cells), rms relative error; the fit applied to the exact profile gives 3.2e-3 (20 cells per R) and 9.2e-4 (30).

| Cells per R | Options | L2 / Omega R | Azimuthal mean | Wall speed (fit) | Inner torque | Shear rms |
| ---: | :--- | ---: | ---: | ---: | ---: | ---: |
| 20 | default | 1.34e-2 | 8.5e-3 | -3.5e-2 | +3.8e-2 | 0.47 |
| 20 | TSC | 1.34e-2 | 8.4e-3 | -3.4e-2 | +3.7e-2 | 0.47 |
| 20 | TSC, compact | 1.35e-2 | 9.9e-3 | -2.0e-2 | +3.6e-2 | 0.47 |
| 20 | TSC, compact, order 2 | 9.6e-3 | 7.8e-3 | -6.6e-3 | +2.9e-2 | 0.38 |
| 30 | default | 7.7e-3 | 4.3e-3 | -4.4e-2 | +1.5e-2 | 0.47 |
| 30 | TSC | 7.8e-3 | 4.3e-3 | -4.4e-2 | +1.4e-2 | 0.47 |
| 30 | TSC, compact | 6.5e-3 | 3.3e-3 | -1.8e-2 | +1.5e-2 | 0.35 |
| 30 | TSC, compact, order 2 | 4.1e-3 | 2.5e-3 | -6.4e-3 | +1.4e-2 | 0.28 |

- TSC alone changes nothing here. Compact viscous gradients cut the wall-speed deficit by about half, and adding order 2 brings it to 0.6 %; at 30 cells per R the velocity error is then 1.9 times smaller than the default (4.1e-3 against 7.7e-3).
- The inner-wall shear from local fits stays at 28 to 47 % for every option and does not converge with resolution. Cause (found by comparing with an earlier build): in `s_compute_ghost_point_velocity` (`src/simulation/m_ibm.fpp`), `master` evaluates a rotating body's wall velocity at the ghost point instead of at the wall point, so the imposed wall speed is \f$\Omega(R-|\phi|)\f$ with \f$\phi\f$ the level set at the ghost point, not \f$\Omega R\f$. The error is up to one cell of radius, about 5 % of the wall speed at 20 cells per R, and about 100 % of the wall shear over the first cell. The ghost pressure routine already uses the wall point. The fix is #2383. With it and `ib_wall_order = 2`, `ib_ip_interp = 2` and `ib_visc_compact = T`, a scratch build gave an inner shear rms of 0.0065 at 20 and 0.0019 at 30 cells per R (second order), against 0.38 and 0.28 above, and an inner torque error of 0.06 % against 2.6 % (a trial of the fix that was not run through this page's checker and is not part of this PR). Ruled out earlier: the estimator (the script that gave the earlier 0.2 to 2 % band, applied to these runs, reproduces `check_couette.py` to four digits), the fit's own error (3.2e-3 at 20 and 9.2e-4 at 30 cells per R on the exact profile) and the start-up (the exact field as initial condition gives the same shear, 0.47 and 0.38).
- The torque is within 4 % of the exact value for every option, with no trend between options.

## Assessment

- **Flat wall:** order 2 is a large gain in the velocity profile and the flow rate (8 to 17 times at 8 to 32 cells across). The default order leaves a large first-order error because the no-slip acts about 0.75 cell outside the wall.
- **Curved rotating wall:** the gain is modest (26 to 42 % in the velocity, 2 to 3 times in the torque). Neither order converges cleanly, because of a wall-speed deficit at the rotating inner wall that order 2 halves but does not remove. The ghost-velocity defect above produces a deficit of this kind; the Mach 0.05 tables were not re-run with the fix, so how much of the deficit it explains there is not verified.
- Order 2 is not uniformly better: it splits the wall force unevenly between two walls when a wall lies inside a cell.

## Known limitations and open issues

- The default order acts about 0.75 cell outside a flat wall; the same code path acts less far out at the curved fixed wall. The cause is not identified (not verified).
- The rotating inner wall keeps a 3 to 7 % wall-speed deficit and a non-converging mean error for both orders on `master`. The ghost-velocity defect above is the identified cause of the rotating-wall shear plateau; the golden of the annulus test changes when the fix merges.
- The wall shear read from near-wall cells (a three-cell quadratic fit in the channel, a cubic fit in the annulus) does not converge for either order. Use the flow rate (channel) and the torque (annulus) as the integral measures.
- 2D, one Mach number and Reynolds number per problem, one machine and compiler. A third grid beyond 40 cells per R and 3D are not measured, so the status stays "partially validated". High-Reynolds-number boundary layers, moving flat walls and slip walls are not measured.
- The rigid-rotation check (an inviscid circle in gas already in rigid rotation) was not reproduced for this page: it needs an initial condition that no case-file patch provides.

## Reproduce

```
./mfc.sh run examples/2D_ibm_plane_poiseuille/case.py -t pre_process simulation -n 1 -- --cells 16 --ntau 12 --wall_order 2
python3 examples/2D_ibm_plane_poiseuille/check_poiseuille.py examples/2D_ibm_plane_poiseuille
./mfc.sh run examples/2D_ibm_taylor_couette/case.py -t pre_process simulation -n 1 -- --cells_per_R 20 --ntau 12 --wall_order 2
python3 examples/2D_ibm_taylor_couette/check_couette.py examples/2D_ibm_taylor_couette
```

Each run writes into the example directory (clear `D/`, `restart_data/` and the `.inp` files between runs). Channel: `--offset 0.37`, `--wall_order 1`. Annulus: `--wall_order 1`, `--ip_interp 2`, `--visc_compact 1`, `--mach 0.01 --re 11 --ntau 4`.
The CI-sized runs are the tests `2D -> IBM -> Taylor-Couette -> ib_wall_order=2` and `2D -> IBM -> Plane Poiseuille -> ib_wall_order=2` (regression goldens, GNU 13 double: 100 steps for the annulus, 300 for the channel; the tolerance is 1e-10, three orders above the 1e-13 largest difference seen between the GNU, Intel, NVHPC and macOS CI lanes and an A100 run).
40 changes: 40 additions & 0 deletions examples/2D_ibm_plane_poiseuille/README.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,40 @@
# 2D Plane Poiseuille Flow Between Two Flat Immersed Walls

Two static rectangle immersed boundaries at y = 0 and y = H = 1 bound a channel periodic in x and driven by a body
acceleration. The gas (rho = 1, sound speed 1, constant viscosity) starts from rest and is run to steady state at peak Mach
number 0.05 and Re = u_max H / nu = 1. The exact solution is u = g y (H - y) / (2 nu), with flow rate g H^3 / (12 nu), so the
profile and the flow rate are known. The example measures `ib_wall_order = 1` (default) and `ib_wall_order = 2` at a flat wall,
on the cell face and 0.37 cell inside it.

`check_poiseuille.py` reads the run directory (serial text output):

python3 examples/2D_ibm_plane_poiseuille/check_poiseuille.py examples/2D_ibm_plane_poiseuille [--tol X]

Wall on a cell face, 12 slowest viscous times (error of the rms velocity over u_max; flow-rate error):

| cells across gap | L2, order 1 | L2, order 2 | flow rate, order 1 | flow rate, order 2 |
|---:|---:|---:|---:|---:|
| 8 | 0.455 | 5.4e-2 | +0.682 | +8.7e-2 |
| 16 | 0.216 | 1.8e-2 | +0.322 | +2.8e-2 |
| 32 | 0.113 | 6.7e-3 | +0.159 | +9.7e-3 |

With the wall 0.37 cell inside a face: 8 cells 0.474 and 7.2e-2, 16 cells 0.223 and 2.0e-2 (orders 1 and 2). The default order acts
as if the no-slip sat about 0.75 cell outside the wall; order 2 removes most of it. The wall force from the face fluxes is
a body-force balance and agrees within 1.2e-3 on a cell face for both orders; with the wall inside a cell the order 2 force splits
unequally between the two walls (+-7 % at 8 cells, +-4 % at 16). The page @ref validation_wall_order_couette has the full tables.

## Run

./mfc.sh run examples/2D_ibm_plane_poiseuille/case.py -t pre_process simulation -n 1 -- --cells 16 --ntau 12 --wall_order 2
python3 examples/2D_ibm_plane_poiseuille/check_poiseuille.py examples/2D_ibm_plane_poiseuille

`case.py` defaults to a CI-sized run (8 cells across the gap, 32 x 28 cells, 300 fixed steps, far from steady state). Options:
`--cells`, `--wall_order`, `--mach`, `--re`, `--offset` (wall offset from a cell face, in cells), `--nx`, `--steps`, `--ntau`. Each
run writes into the example directory; remove `D/`, `restart_data/` and the `.inp` files between runs. Use one rank (serial text
output). The suite registers the CI-sized run as `2D -> IBM -> Plane Poiseuille -> ib_wall_order=2` (a regression golden).

## Limits

Static walls, one Mach number and Reynolds number, 2D, one machine and compiler (NVIDIA A100, NVHPC 25.11, double precision). The
shear read from the three cells nearest a wall does not converge for either order. No high-Reynolds-number boundary layer and no
moving flat wall was measured.