What and why

The Anscombe amplitude loss only took data in photons, while poisson_loss and mixed_poisson_gaussian_loss take detector units plus a gain. Switching between them meant changing the data units. Now all three noise losses use the same units.

  • PtyLab/Engines/GradientEngine/losses.py: amplitude_loss gets a gain argument. With anscombe_offset_switch=True the offset is now $c = 3g/8 + \sigma^2/g$ (generalized Anscombe transform, Mäkitalo and Foi 2013). Without the shift, gain must stay 1. Shorter module and docstrings for losses.
  • PtyLab/Engines/GradientEngine/engine.py: readoutSigma is in detector units for every loss.
  • docs/differentiable/overview.md: lists gain for amplitude_loss and drops the photon-only note.

How it was tested

New test_generalized_anscombe_stabilizes_the_variance (variance $g/4$ at 20 and 500 photons, three gain/σ pairs), plus gain cases in the existing Anscombe tests. uv run pytest tests/Engines: 230 passed, 1 skipped.

Notes

With gain=1 (the default) results are unchanged.

@ShantanuKodgirwar
ShantanuKodgirwar merged commit 20aa79e into main Nov 23, 2026
6 checks passed
@ShantanuKodgirwar
ShantanuKodgirwar deleted the gain-unit-GAT branch November 23, 2026 17:07