SensorPush

SensorPush recently introduced a API to query the temperature and humidity samples recorded by their smart sensors via G1 WIFI GATEWAY - As long as the API is in beta stage, you have to contact support to get access!

This Python 3 tool can query the API and save the temperature and humidity time series to a time series database so it can easily be plotted with Grafana.

If you don't have an G1 WIFI Gateway and still want to plot your temperature, you can use another little tool I wrote to feed the CSV file which you can export via the Android App to InfluxDB.

Grafana

sensorpushd.py - Unified Daemon (Recommended)

sensorpushd.py is the unified replacement for the individual scripts. It supports InfluxDB 2, InfluxDB 3, and VictoriaMetrics in a single tool — including writing to multiple backends simultaneously. It can run either as a one-shot command (for cron) or as a continuous daemon (managed by systemd).

Changes and upgrade notes are listed in CHANGELOG.md. The offline test suite runs with python3 -m unittest discover -s tests.

Installation

# Required for all backends:
pip install requests

# Only install what you need for your chosen backend:
pip install influxdb-client      # for InfluxDB 2
pip install influxdb3-python     # for InfluxDB 3
# VictoriaMetrics needs no extra packages

Quick Start

# First run creates a config template at ~/.sensorpushd.conf
./sensorpushd.py

# Edit the config file with your SensorPush credentials and backend settings
nano ~/.sensorpushd.conf

# One-shot: fetch last day of data (backward compatible with cron)
./sensorpushd.py -b 1d --backend victoriametrics

# Write to multiple backends simultaneously
./sensorpushd.py -b 1d --backend victoriametrics influxdb3

# Daemon mode: continuous polling every 5 minutes
./sensorpushd.py --daemon --interval 300

# Dry run to preview data without writing
./sensorpushd.py -b 1h -x --backend victoriametrics

# List your sensors, including the sensor_id each one is stored under
./sensorpushd.py -l

Migrating from the old scripts

Your existing config files work directly:

# Use existing InfluxDB 2 config
./sensorpushd.py -c ~/.sensorpush.conf -b 1d

# Use existing VictoriaMetrics config
./sensorpushd.py -c ~/.sensorpush_vm.conf -b 1d

Coming from sensorpush_vm.py (or sensorpush.py): those scripts stored the full SensorPush id in sensor_id, sensorpushd.py stores the shortened form described in Stored sensor ids. Each sensor therefore continues in a new series. Panels that select or group by sensor_name are unaffected; queries that filter on sensor_id need both forms to cover the whole history.

Configuration

The new unified config file (~/.sensorpushd.conf) supports all backends. Only configure the sections for the backend(s) you use. To write to multiple backends simultaneously, set TYPE to a comma-separated list. All backends are written with the MEASUREMENT_NAME of the first backend in TYPE (the daemon warns at startup if the sections disagree):

[SENSORPUSHAPI]
LOGIN = your_email@example.com
PASSWD = your_password

[BACKEND]
TYPE = victoriametrics
# For multiple backends: TYPE = victoriametrics, influxdb3

[INFLUXDB2]
MEASUREMENT_NAME = SensorPush
URL = http://localhost:8086
TOKEN = your_token
ORG = your_org
BUCKET = sensorpush
VERIFY_SSL = False
# Optional, see "Storing the full sensor id" below. Default: False
SENSOR_UID = False

[INFLUXDB3]
MEASUREMENT_NAME = SensorPush
URL = http://localhost:8181
DATABASE = sensorpush
TOKEN = your_token
VERIFY_SSL = False
SENSOR_UID = False

[VICTORIAMETRICS]
MEASUREMENT_NAME = SensorPush
URL = http://localhost:8428
VERIFY_SSL = False
SENSOR_UID = False

[DAEMON]
INTERVAL = 300
# How far every poll reaches back; at least 1h (see "Daemon features")
POLL_BACKLOG = 1h
# When to re-read a gap after it closed; 0 = off (see "Gap re-checks")
RECHECK_GAPS = 1h, 6h, 1d, 3d, 7d
# The shortest silence of a sensor that counts as a gap
RECHECK_MIN_GAP = 20m
# Failed calls in a row after which a gap's last re-read is given up
RECHECK_GIVE_UP_AFTER = 48

[CUTOFFS]
# Optional, no cut-off by default: sensor error values not to store, see
# "Sensor error values and cut-offs".  <METRIC>_FLOOR and <METRIC>_CEILING
# for TEMPERATURE, HUMIDITY, PRESSURE, DISTANCE, DEWPOINT, VPD, ABS_HUMIDITY,
# ALTITUDE, VOLTAGE and RSSI.  The recommended values for a failed chip's
# error values; check your own data before you set them:
# TEMPERATURE_FLOOR = -40
# HUMIDITY_FLOOR = 0

[MISC]
MY_ALTITUDE = 0.0
FORCE_IPv4 = False

Stored sensor ids

SensorPush sensor ids look like 123456.7890123456789012: the device id, a dot and about 16 more digits. The sensor_id tag stores str(float(id)), Python's shortest form of the nearest floating-point number, which keeps 15-17 significant digits:

SensorPush id (API and app) stored sensor_id
123456.7890123456789012 123456.78901234567
12345678.9012345678901 12345678.901234567

The part before the dot is always kept in full, and the mapping is fixed, so any id can be turned into its stored value:

./sensorpushd.py -l                                          # every sensor, with its stored sensor_id
python3 -c 'print(float("123456.7890123456789012"))'         # 123456.78901234567

sensor_id does not change when you rename a sensor, so it is the key for one particular device. sensor_name follows renames, and the same name can later be given to a replacement sensor, so it is the key for a place.

This format is kept on purpose. Every existing series, every query or alert that filters on sensor_id, and the daemon's own gap detection depend on it; storing a different value would start new series and make gap detection blind to existing data (see issue #9). To store the full id as well, see Storing the full sensor id.

Which script stored which form. sensorpush.py and sensorpush_vm.py stored the full id, sensorpush2.py and sensorpushd.py store the shortened one. If you switched between them, a sensor's history is split across both values. To query all of it, match both:

-- InfluxQL
SELECT mean("temperature") FROM "SensorPush"
  WHERE ("sensor_id" = '123456.78901234567' OR "sensor_id" = '123456.7890123456789012') AND $timeFilter
  GROUP BY time($__interval)
// Flux (use == ... or ==, not contains(), which is not pushed down to storage)
|> filter(fn: (r) => r.sensor_id == "123456.78901234567" or r.sensor_id == "123456.7890123456789012")
-- SQL (InfluxDB 3)
SELECT ... FROM "SensorPush" WHERE sensor_id IN ('123456.78901234567', '123456.7890123456789012')
# PromQL / MetricsQL - label regexes are anchored; escape the dots
avg by (sensor_name) (SensorPush_temperature{sensor_id=~"123456\\.78901234567|123456\\.7890123456789012"})

For a quick look, the device id alone also matches both forms, e.g. InfluxQL "sensor_id" =~ /^123456\./. Avoid it in saved queries: it also matches any earlier id the same device had if it was ever removed and registered again.

Storing the full sensor id (SENSOR_UID)

Set SENSOR_UID = True in a backend's section ([INFLUXDB2], [INFLUXDB3], [VICTORIAMETRICS], or [INFLUXDBCONF] / [VICTORIAMETRICSCONF] in the legacy config files) and every point written to that backend from then on also carries the full id as the tag sensor_uid. It is off by default, and sensor_id keeps its value either way.

What enabling it changes:

  • New series. Like renaming a sensor, every sensor continues in a new series from the switch on; points stored before it have no sensor_uid. Queries that filter or group by sensor_id or sensor_name, and the shipped dashboards, keep showing one line. Queries that keep every tag apart - InfluxQL GROUP BY *, Flux without group(), PromQL/MetricsQL without sum by/avg by - show the old and the new series side by side.
  • A one-time overlap. After the restart that enables it, the daemon re-reads the last POLL_BACKLOG (one hour), or more if it was stopped for longer than that. Those points are then stored with and without sensor_uid: mean() is unaffected, count() and sum() double for that stretch. The same happens whenever time from before the switch is fetched again, e.g. a one-shot run with -s/-p, or a back-fill for a second backend that had fallen behind.
  • Nothing else. Gap detection and back-fills still key on sensor_id and find old and new series alike.
  • Backend support. Early InfluxDB 3 Core builds (2024-12 to 2025-03) rejected writes that add a new tag to an existing table, and InfluxDB 3 Enterprise databases (or InfluxDB Cloud buckets) with an explicit schema need the tag declared first. If a backend rejects the writes, its log shows write errors; set SENSOR_UID = False again.

Turning it off again splits the series once more, the same way. migrate_influx2vm.py copies sensor_uid as a label.

Live and final samples

For the newest minutes the SensorPush API serves most readings twice: first as a live copy at an irregular second, and later as the sensor's own sample, on a fixed second of the minute and usually within a minute of the copy (before or after it, depending on the sensor). After about half an hour the API normally serves only the sensor's own samples, so a later re-read or back-fill returns only those.

The daemon stores every sample the API serves, except values [CUTOFFS] marks as errors (see "Sensor error values and cut-offs"). With the default settings a sensor therefore has about twice as many points as a re-read returns. Data written by versions with a 10-minute backlog contains live copies too, and so can data from the old scripts; a back-fill does not remove them. This is on purpose: the live copies are the only data for the newest minutes, and some readings are never served in any other form. No stored field marks a live copy. In the API's answer an HT1's live copy names the gateway that relayed it, while its own sample leaves gateways empty, but the daemon does not store that field, and on HT.w and HTP.xw both carry it. In the database the best hint is the timestamp: a sensor's own samples sit on one second of the minute (which can shift after a gap), and live copies almost never do.

What this means for queries:

  • Averages, minimum and maximum are practically unaffected, the newest value is more current, and the shipped dashboards need no change.
  • count() counts both copies. To check completeness, count the minutes that have data rather than the points, and compare a sensor with itself, not with other models. HT.w and HTP.xw sensors have data in every minute. HT1 sensors seem to leave a reading out of their own record when neither temperature nor humidity has changed: polled live, most of mine have data in 40 to 55 minutes of an hour (the live copies fill part of the holes), and a re-read or back-fill returns fewer. On an HT1 a missing minute is not a lost reading, but a long silence points to missing data: in more than three months of complete record, no working HT1 of mine was silent for more than about an hour, and no HT.w or HTP.xw for more than about a minute.
  • derivative(), difference() and similar functions on raw points spike, because a live copy and the neighbouring sample can be seconds apart and one reading step different. Aggregate first.
-- InfluxQL: minutes with data, per sensor
SELECT count("c") FROM (
  SELECT count("temperature") AS "c" FROM "SensorPush"
  WHERE $timeFilter GROUP BY time(1m), "sensor_name" fill(none)
) WHERE $timeFilter GROUP BY "sensor_name"

-- InfluxQL: rate of change of 5-minute means
SELECT derivative(mean("temperature"), 1m) FROM "SensorPush"
  WHERE $timeFilter GROUP BY time(5m), "sensor_name"

-- InfluxQL: silences longer than an hour, per sensor (one still going on is not listed)
SELECT "gap" FROM (
  SELECT elapsed("temperature", 1m) AS "gap" FROM "SensorPush"
  WHERE $timeFilter GROUP BY "sensor_name"
) WHERE "gap" > 60 GROUP BY "sensor_name"

Sensor error values and cut-offs

A sensor whose temperature and humidity chip fails keeps reporting, and the API serves its error values like any reading: an HT1 reports -46.83 or -46.84 °C (the chip's raw 0: -46.85 + 175.72 x 0) with 0 % humidity (-5.97 % in data from before about 2023), an HTP.xw exactly -40 °C with 0 %. The dewpoint (0), vpd (0.1 to 0.2) and abs_humidity (0) of such a point are computed from those and are garbage too. An HTP.xw's pressure stays valid: only its temperature and humidity chip failed. Some points have only the humidity wrong (0 % or -5.94 %), with a valid temperature.

The daemon stores every value unless the optional [CUTOFFS] section marks it as an error value. It holds a floor and a ceiling per metric, <METRIC>_FLOOR and <METRIC>_CEILING, named after the stored field: TEMPERATURE, HUMIDITY, PRESSURE, DISTANCE, DEWPOINT, VPD, ABS_HUMIDITY and ALTITUDE for the samples, VOLTAGE and RSSI for the status records (measurement <MEASUREMENT_NAME>_V).

  • A value at or below its floor, or at or above its ceiling, is an error value and is not stored. The cut-off itself counts as an error, so a floor can be set to a sensor's error value: TEMPERATURE_FLOOR = -40 drops -40 and -46.84 °C, HUMIDITY_FLOOR = 0 drops 0 % and -5.97 %. The same goes for a ceiling: HUMIDITY_CEILING = 100 would drop real readings of 100 %.
  • The values are in the unit the daemon stores: °C for temperature and dewpoint, %, mBar for pressure and vpd, g/m³, m for altitude and distance, V and dBm. With -n/--noconvert the daemon stores the API's units instead: °F, inHg, kPa and ft (-40 is the same in °C and °F).
  • Per value, not per sample: the other values of a sample are stored, except those computed from an error value, whether the API or the daemon computed them - dewpoint, vpd and abs_humidity when temperature or humidity is one, abs_humidity and altitude when pressure is. A sample left with none of temperature, humidity, pressure and distance is not stored at all (its altitude alone means nothing), nor is a status record left with neither voltage nor rssi. So an HT1 error point is not stored, an HTP.xw error point keeps its pressure and altitude, and a point with only the humidity wrong keeps its temperature.
  • A record without a field is not affected by that field's cut-offs. A status record carries a voltage of 0.0 when the API reports none: an ordinary value here, so VOLTAGE_FLOOR = 0 drops it.
  • Without the section, or with a key missing or left empty, there is no cut-off for that bound - the default for every bound, so a config without the section stores exactly what it did. A value that is not a number, an unknown key (a typo) or a floor at or above the ceiling of the same metric stops the daemon at startup, in every mode, with a one-line error naming the key and listing the valid ones; so does a section named like it but not exactly [CUTOFFS], such as [cutoffs] or [CUTOFF] (section names are case-sensitive). Legacy config files may have a [CUTOFFS] section too.
  • Every run that stores records applies them: one-shot runs, polls, back-fills, gap re-reads and the status records; a dry run shows what would be stored. Gap detection still sees every sample the API serves, so a sensor that sends only error values has no gap, and it does not look as if it had fallen behind: the deep scan counts its newest sample, stored or cut off, as its last data, and a backend that took the batches of such samples as holding everything up to them, so even while every sensor polled sends only error values, a deep scan fetches no more than without cut-offs. After a restart, which forgets what was cut, the time since the last stored reading may be fetched once more, and such a sensor back-filled once.
  • Each batch that cut values logs one INFO line with the counts per sensor and metric. The first value cut per sensor and metric logs a WARNING with the value, its time and the key, once per process.
  • The daemon never changes points already stored: error values written before the section was set stay until they are deleted in the database.

On one installation (18 sensors, 2018 to 2026, 5,081 error points: 5,058 with both temperature and humidity at the error value, 1,698 of them HTP.xw points with a valid pressure of 1011 to 1031 mBar, and 23 with only the humidity wrong), TEMPERATURE_FLOOR = -40 and HUMIDITY_FLOOR = 0 catch every error value and no real reading: the coldest real temperature there is -21.32 °C (a freezer), no real humidity is at or below 0.5 %, and SensorPush rates HT1, HT.w and HTP.xw sensors from -40 °C. That is the recommendation; check your own data before setting them, as no cut-off is set by default.

Gap re-checks

After an outage the cloud fills in the past late. When a gateway, the internet or the power comes back, the gateway uploads what its sensors recorded meanwhile: a small backlog usually within about an hour, the history of an HT1 sensor sometimes hours or weeks later. One read right after the outage finds only part of it.

So the daemon notes every gap it sees in a sensor's data, a silence of more than RECHECK_MIN_GAP (default 20 minutes, at least 15), and reads it again, with an hour on either side, 1 hour, 6 hours, 1 day, 3 days and 7 days after the sensor reported again (RECHECK_GAPS). It writes whatever the cloud holds by then: the same points the polls write, with the same tags, fields and timestamps.

It also notes what a poll did not reach. A poll looks back an hour, and the API leaves out up to 15 minutes after the start of a window in the newest hour (see "Complete polls"). A sensor's samples right after the last one the daemon saw can lie in that stretch, even when no gap shows: after the sensor was silent for about 45 minutes or more, after the daemon paused that long, and with polls more than 30 minutes apart. The daemon reads such a stretch once more at the first re-read time, an hour later, and writes what it holds. Only if that read shows a gap, or could not read all of it, is the stretch read on like a gap.

What it costs:

  • No API calls while no sensor has a gap and INTERVAL is 30 minutes or less, or 60 minutes or more with the default DEEP_SCAN_INTERVAL of 1h.
  • With polls more than 30 and less than 60 minutes apart, the stretches a poll did not reach cost calls also without any gap. Measured on 18 sensors (12 HT1, 2 HTP.xw, 4 HT.w) with the default DEEP_SCAN_INTERVAL: 4 to 13 calls a day at an INTERVAL of 35 minutes and 26 to 35 at 40 (more when HT1 live copies are further apart), 16 at 45, 14 at 50, 13 at 55 and 12 at 59. Below 45 minutes they find nothing on a normal day. From 45 minutes on they fetch what the API left out after each poll's start: at 59 minutes about 1,100 samples a day on those 18 sensors, which are lost without them. With an INTERVAL of 60 minutes or more and a longer DEEP_SCAN_INTERVAL it is up to one call per poll (20 a day at 60 minutes with 6h).
  • A pause of the daemon of 40 to 60 minutes costs one call at most.
  • One call per re-read of a gap up to about 9 hours long (with the default -t 720), one more per further 11 hours. A call serves every gap that fits in its window, so after an outage of the whole installation one call covers all sensors, also when they come back minutes apart.
  • At most 6 re-read calls and about 2 minutes per cycle (2 calls with the default --delay 60). Long gaps are read over several cycles while the polls go on.
  • An HTP.xw or HT.w gap that a re-read finds complete (a sample every minute) is not read again, and a gap longer than a day whose first re-read found nothing is next read after 3 days (if RECHECK_GAPS has a read that late).
  • After a failed re-read call, re-reads pause for one polling interval, longer after each further failure in a row, up to an hour; any call that works starts that over. They also wait while the polls fail, and while any backend fails its writes (checked before each call), so that every backend gets what they write.
  • A window that fails twice in a row is then read alone: one sensor per call, so that one sensor's data cannot fail the others' call. The first of these reads decides for the others: if it works, they are read together again (once per window and re-read); if it fails, they are read alone. Apart from that first read, reads alone come after the gaps read together and hold up none of them. Reads alone pause on their own after a failure, with the same pauses: however many windows keep failing, they make at most one failed call per pause, about 27 a day at an INTERVAL of 5 minutes. A window that fails 3 times in a row is left for the gap's next re-read; the gap's next window is then read alone and left after one failed call.
  • The last re-read has no next one. There a window that fails 3 times is kept and tried again, alone. It is given up by the 48th failed call in a row of the gap's last re-read (RECHECK_GIVE_UP_AFTER: the failed calls of all its windows together, until a read of the gap works); each later window of the gap is then given up after one failed call. The first window to be given up still fails 3 times in a row first, also with a RECHECK_GIVE_UP_AFTER below 3. These are calls, not time: waiting uses none of them, and while every re-read call fails, the windows read alone share one pause, which grows to an hour, so one gap outlasts nearly two days of failing calls (about 43 hours at an INTERVAL of 5 minutes), several gaps longer, and a gap that never works costs at most 48 failed calls plus one per remaining window. A window that fails while other calls work is tried again sooner, and given up sooner. The count is kept in state.json, so a restart grants no fresh tries. A window whose last write a backend refused is given up sooner: by a refused call more than a day after the last re-read time, as the backend will most likely go on refusing it, and the gap's windows that it would take wait behind it. A re-read whose later times all went by while re-reads could not run is the last one too. A re-read that had begun before them and was cut short (the Pi off, a backend failing) is not: the last re-read still follows, and reads the whole gap again.
  • Of the reads alone after the gaps read together, windows read for the last time get every other one while other windows wait too: windows kept on a gap's last re-read (see the previous point), and the other windows of a gap's last re-read that failed twice and are read alone. A window whose last write a backend refused does not take that turn: the backend will most likely refuse it again (its points are older than the backend keeps, say, or a field type conflict), and those tries would halve the speed of the other windows. It waits with them and still gets its calls; a later call that fails before the write (at the API, say) gives it the turn back.
  • The other windows read alone go one gap at a time. In each of the two groups, windows not read alone yet go first, the most overdue first, then the gap that began first; then the one read alone least recently. A kept window whose last write a backend refused, more than a day after the last re-read time (or with one try left), counts as not read alone yet if its gap has a next window: its next refused call gives it up, and its gap goes on from there. A gap's next window after one that was left has not been read alone yet, so gaps whose windows all fail, such as gaps whose records a backend keeps refusing, are crawled through one after another: one window per pause of the reads alone (up to an hour), one per two pauses while a window that takes every other read is due. The windows that wait get their calls later. That costs nothing while the cloud and the bucket still hold their history - waiting uses none of a gap's tries - except for a window read for the last time whose last write a backend refused: it waits too, and after the day past the last re-read time one refused call gives it up. With a bucket retention, history can age out meanwhile (see "Limits").
  • An answer cut off by -q/--qlimit is read again in smaller windows; one cut off even in 30-minute windows counts as a failed call.

The gaps are kept in state.json (key rechecks, ignored by older releases), so a restart does not lose them; re-reads that fell due meanwhile are done once, together. A sensor keeps at most 40 gaps, all sensors together 1,000; beyond that the closest gaps are merged into one, so none is dropped.

RECHECK_GAPS = 0 (or off, no, none, false, empty) turns the re-checks off: the daemon then behaves exactly as without them, and state.json gets no new key. Legacy config files (~/.sensorpush.conf, ~/.sensorpush_vm.conf) may have a [DAEMON] section for this; RECHECK_GAPS, RECHECK_MIN_GAP and RECHECK_GIVE_UP_AFTER are the only keys read from it. An invalid value stops the daemon at startup with a one-line error. One-shot runs ignore all three keys.

Limits:

  • Horizon. Samples that reach the cloud more than 7 days after the gap closed are not fetched; a one-shot run with -s/-p still gets them.
  • On-board storage. Sensors keep about 20 days (HT1), 30 days (HTP.xw) or 45 days (HT.w) of samples; older parts of a longer gap are not re-read.
  • Bucket retention. InfluxDB 2 stores the points of a write that are inside the bucket's retention and drops the older ones, answering HTTP 422 ("partial write: points beyond retention policy dropped=N"). The daemon counts such a write as done - one WARNING the first time, INFO lines after it - so the polls, back-fills and re-reads of a gap that reaches beyond the retention go on at their usual pace, but nothing older than the bucket keeps is stored, and history that ages out of the bucket before its re-read is lost. A bucket that keeps longer than the longest outage plus 7 days and an hour avoids that. VictoriaMetrics drops samples outside its retention without an error. A write a backend refuses for another reason (any other InfluxDB 2 error, a field type conflict say, or an InfluxDB 3 error, also for points older than it keeps) still fails: the re-reads get through windows a backend keeps refusing one failed call each - on a gap's last re-read from a day after its time on - one window per pause of the reads alone (up to an hour), and history that ages out of a bucket meanwhile is lost, also that of the gaps that wait behind such a crawl.
  • Short buckets. A re-read writes only when it finds more samples than the reads before it, and it writes from an hour before the gap. With a bucket that keeps less than the last re-read time plus the gap and an hour (with the default RECHECK_GAPS, any bucket of 7 days or less), a last re-read that finds new samples - history uploaded after the 3d read, say - writes points older than the bucket keeps. InfluxDB 2 drops those and stores the rest, so that call costs nothing more; with a bucket of 7 days or less (the default RECHECK_GAPS) the rest is none of the gap. A gap whose history came by the 3d read costs nothing at all: its last re-read finds nothing new and writes nothing. At startup the daemon reads the bucket's retention, and if it is at or below the last RECHECK_GAPS time, it logs a WARNING with the times to set (a token without read access to buckets only skips the check). Set RECHECK_GAPS to times inside the retention, e.g. 1h, 6h, 1d, 3d for a 7-day bucket.
  • A write refused for a moment. A window read for the last time whose write a backend refused only for a moment (during a restart, say) loses its turn while other windows are read alone, such as those of a gap crawling through windows a backend keeps refusing: it waits with them. It is lost if its next call more than a day after its last re-read time is refused again (one that fails at the API keeps it), or if, with a bucket retention, its history ages out while other gaps' windows go first. Measured with a backend that refused every point older than 14 days, while the gap of a 30-day outage was crawled through: a 2-hour gap whose last re-read a backend refused for 2 hours got its next call only 40 hours after its last re-read time.
  • Re-read calls failing for days. A gap's last re-read is given up by its 48th failed call in a row (RECHECK_GIVE_UP_AFTER, see above). While SensorPush answers the polls but fails the re-read calls, the windows read alone share one pause, which grows to an hour, so one gap outlasts nearly two days of such a spell, several gaps longer; history is lost only when the spell outlasts a gap's tries. While the polls fail too, re-reads make no calls and use no tries. Calls that fail now and then do not add up: a read that works starts the count over (simulated: the last re-read of a 21-day gap whose calls failed at random, 3 to 6 in 10 of them, and of a 40-day gap, 3 or 4 in 10, wrote all of the history in each of 120 runs). A window whose records a backend keeps refusing is given up by a refused call more than a day after the last re-read time (see above). Measured: 4 to 12 HT1 gaps at their last re-read during spells of 24 to 30 hours of failing re-read calls, also with another gap crawling meanwhile and with restarts, and the 18 sensors of one 30-hour outage at their last re-read during spells of up to 36 hours: all of that history written in each of 85 runs (the previous rule, which gave a window up by its first failed call a day after the last re-read time: 19 to 100 %, 87 % in all).
  • Windows that never work, beside a crawl. A window read for the last time whose calls keep failing at the API takes every other read alone until its gap's tries are used up (RECHECK_GIVE_UP_AFTER, nearly two days for one gap), where the previous rule gave it up a day after the last re-read time. Meanwhile another gap that crawls through windows a backend refuses goes at half speed, and with a bucket retention more of its history can age out first. This needs a backend that refuses old points: InfluxDB 2 no longer does (see "Bucket retention"), VictoriaMetrics never did. Measured with a backend that refused every point older than 14 days, beside 4 such windows: in 2 of 21 setups the crawling gap kept 22 and 43 % of its history instead of 63 % (all 21: 63.1 % instead of 65.9 %); with InfluxDB 2's behaviour, the same in all 21.
  • HT1 data not seen live. HT1 sensors seem to leave a reading out of their own record when neither temperature nor humidity has changed, so their own samples can be an hour apart. While the daemon polls at most 25 minutes apart it also sees the live copies, at most about 13 minutes apart, and a 20-minute silence is a real gap. In data it did not see live - from its own downtime, across a restart, or with polls more than 25 minutes apart - an HT1 gap counts only from 90 minutes, also in a stretch a poll did not reach. So an HT1 silence of 20 to 90 minutes while the daemon was down too (a power cut that took the Pi and the gateways down together) is not re-read. HTP.xw and HT.w sensors record every minute and always use RECHECK_MIN_GAP.
  • VictoriaMetrics duplicates. Re-reads write some points again; with polls 45 to 59 minutes apart, the reads of what a poll did not reach write about 80 % more points than the polls alone (measured on 18 sensors). InfluxDB overwrites them with identical values; VictoriaMetrics without -dedup.minScrapeInterval keeps them as duplicates, as it already does for the hour each poll overlaps the previous one. Averages, minimum and maximum are unaffected; count() is not.

Running as a systemd service

# Copy and edit the service file
sudo cp sensorpushd.service /etc/systemd/system/
sudo nano /etc/systemd/system/sensorpushd.service  # adjust paths

# Enable and start
sudo systemctl daemon-reload
sudo systemctl enable --now sensorpushd

# Check status and logs
sudo systemctl status sensorpushd
sudo journalctl -u sensorpushd -f

Daemon features

  • Multi-backend: Write to multiple databases simultaneously; each backend is independent — one failure does not block the others
  • Complete polls: Every poll reaches back at least an hour (POLL_BACKLOG, default 1h). The SensorPush API hands out each sensor's samples in chunks of about 15 minutes and selects a chunk by its start time, so a query from T returns only chunks that started at or after T. A shorter window silently misses most samples; shorter settings are raised to 1h with a warning. If you ran an earlier version with a 10-minute backlog, see CHANGELOG.md for how to back-fill what it missed. The newest minutes also come as live copies, which are stored too; see Live and final samples
  • Gap-filling: If the API or database was unavailable, the daemon automatically detects the gap on the next successful cycle and back-fills the missing data. It finds the gap by asking each backend for its newest stored point, so the token needs read access as well as write access. If a backend cannot be asked (a timeout, missing permission, or it is failing writes at that moment), the daemon resumes from the end of the last collection known to have completed (kept in state.json) instead of assuming an empty database. That mark is kept for the collector as a whole: a backend that rejected writes while another one kept working catches up once it accepts writes and answers lookups again. VictoriaMetrics needs v1.52 or later (tlast_over_time())
  • Gap re-checks: Gateways upload the samples an outage missed late, so the daemon reads every gap in a sensor's data again 1h, 6h, 1d, 3d and 7d after it closed (RECHECK_GAPS, 0 turns it off). Without gaps this costs no API calls at an INTERVAL of 30 minutes or less, or of 60 minutes or more with the default DEEP_SCAN_INTERVAL; see Gap re-checks
  • Error-value cut-offs: Optional [CUTOFFS] floors and ceilings per metric keep sensor error values (HT1 -46.8 °C, HTP.xw -40 °C, with 0 % humidity) out of the database, value by value; off by default (see "Sensor error values and cut-offs")
  • Bucket retention: A write InfluxDB 2 answers with "points beyond retention policy" counts as done, and at startup the daemon warns if RECHECK_GAPS reaches beyond the bucket's retention (see "Gap re-checks")
  • Graceful shutdown: Responds to SIGTERM/SIGINT for clean shutdown
  • Error recovery: Retries with exponential backoff on API or backend failures; never exits on transient errors
  • Token refresh: Proactively re-authenticates before the OAuth token expires
  • Configurable logging: Use --log-level and --log-file for production logging

CLI reference

./sensorpushd.py --help

All arguments from the old scripts are preserved (-s, -p, -b, -t, -q, -d, -l, -g, -i, -n, -x, -v), plus new ones:

Argument Description
--backend One or more of: influxdb2, influxdb3, victoriametrics
--daemon Run as a continuous daemon
--interval Polling interval in seconds (default: 300)
-c/--config Path to config file
--log-level DEBUG, INFO, WARNING, or ERROR
--log-file Log to file instead of stderr

Legacy Scripts (Deprecated)

The individual scripts are still available but deprecated in favor of sensorpushd.py. They are kept as they are; changing what they store would split their users' series. Do not run them alongside the daemon against the same database: they store sensor_id in a different form.

Script Database Config File Stores sensor_id as
sensorpush.py InfluxDB 1.x ~/.sensorpush_legacy.conf full id
sensorpush2.py InfluxDB 2.x ~/.sensorpush.conf str(float(id)), like sensorpushd.py
sensorpush_vm.py VictoriaMetrics ~/.sensorpush_vm.conf full id

sensorpushd.py has no InfluxDB 1.x backend, so sensorpush.py has no direct replacement.

Grafana Dashboards

Example Grafana dashboards are included:

  • SensorPush-GrafanaDashboard.json - Dashboard for InfluxDB
  • SensorPush-GrafanaDashboard-vm.json - Dashboard for VictoriaMetrics (Prometheus data source)

Both select sensors by sensor_name and combine all series of a name into one line, so a renamed sensor, a switch of the sensor_id form or enabling SENSOR_UID does not show up as duplicate lines. (A dashboard you imported earlier is not updated by pulling a new version of the file; re-import it to get the change.)

Migration from InfluxDB to VictoriaMetrics

If you have existing SensorPush data in InfluxDB and want to migrate to VictoriaMetrics, use the migrate_influx2vm.py script:

# migrate_influx2vm.py --help
usage: migrate_influx2vm.py [-h] [-c CONFIG] [--ifdb-config IFDB_CONFIG] [--vm-config VM_CONFIG]
                            [--start START_TIME] [--end END_TIME] [--all]
                            [--batch-size BATCH_SIZE] [--chunk-days CHUNK_DAYS]
                            [--dry-run] [--verbose]

Migrate SensorPush data from InfluxDB 2.x to VictoriaMetrics

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Read both databases from a unified sensorpushd.py config
                        ([INFLUXDB2] and [VICTORIAMETRICS] sections)
  --ifdb-config IFDB_CONFIG
                        Path to InfluxDB config file (default: ~/.sensorpush.conf)
  --vm-config VM_CONFIG
                        Path to VictoriaMetrics config file (default: ~/.sensorpush_vm.conf)
  --start START_TIME    Start time (ISO format, or relative written as --start=-7d)
  --end END_TIME        End time (ISO format, default: now)
  --all                 Migrate all data from earliest available
  --batch-size BATCH_SIZE
                        Batch size for writes (default: 10000)
  --chunk-days CHUNK_DAYS
                        Days per chunk for large migrations (default: 7)
  --dry-run             Preview migration without writing data
  --verbose             Show detailed output

Example usage:

# Migrate all historical data
python migrate_influx2vm.py --all

# Migrate everything since a date
python migrate_influx2vm.py --start="2026-01-01T00:00:00Z"

# Migrate the last 30 days (relative times need the '=' form)
python migrate_influx2vm.py --start=-30d

# Preview migration without writing, reading the daemon's unified config
python migrate_influx2vm.py --config /etc/sensorpushd.conf --all --dry-run

The script copies sensor_id exactly as InfluxDB holds it, so history from different scripts keeps its form (see Stored sensor ids).

CSV import

# sensorpush_csv-import.py --help
usage: sensorpush_csv-import.py [-h] [-f CSVFILE] [-s SENSORNAME]
                                [-i SENSORID] [--float-id] [-d] [-c CHUNKS]

Reads a CSV file exported from the SensorPush Android App and stores the temp
and humidity readings in InfluxDB

optional arguments:
  -h, --help            show this help message and exit
  -f CSVFILE, --csvfile CSVFILE
                        CSV file exported from the SensorPush Android App
  -s SENSORNAME, --sensorname SENSORNAME
                        Sensor name
  -i SENSORID, --sensorid SENSORID
                        Sensor id, in the form your collector stores it, so the
                        import lands in the same series
  --float-id            Store the id the way sensorpushd.py and sensorpush2.py do,
                        str(float(id)), e.g. 123456.7890123456789012 -> 123456.78901234567
  -d, --dryrun          Do not write anything to InfluxDB - just print what
                        would have been written
  -c CHUNKS, --chunks CHUNKS
                        Write data in chunks to InfluxDB to not overload e.g.
                        a RaspberryPi