PlotTTY reads text from your device and plots the numbers in it. Connect over Serial, J-Link RTT, TCP/IP, or UDP, then choose the values you want to follow.
Download PlotTTY · Changelog · Get started · Plot controls · Run from source
- Connections: Serial, J-Link RTT, TCP/IP, and UDP. Each connection gets its own tab with separate settings, plots, and console.
- Extraction rules: Named values, delimited fields, first-number matching, and regex. Generate rules from sample text or set them up manually.
- Plots: Analog, Digital, and Dots modes, with pan, zoom, and auto scroll.
- Measurements: Select a time range for its average and sample count, calculated from the original samples.
- Console: Text search, receive timestamps, and command history.
- Recordings: Save console logs and
.plottycaptures. Reopen captures or export their values as CSV.
Download your platform's package from the latest release and extract it. Python and the required packages are included.
| Platform | Package | Launch |
|---|---|---|
| Windows x64 | windows-x64.zip |
Run PlotTTY.exe; keep the app/ folder and supporting files beside it. |
| macOS Apple silicon | macos-arm64.zip |
Open PlotTTY.app. |
| macOS Intel | macos-x64.zip |
Open PlotTTY.app. |
| Linux x64 | linux-x64.tar.gz |
Run ./PlotTTY from the extracted folder. |
- Choose Serial, J-Link RTT, TCP/IP, or UDP in the connection bar.
- Open Settings, enter your connection details, and click Save settings.
- Turn on File → Log to file if you want to save the session.
- Click Connect. Open View → Console to see incoming text.
- Paste a sample line into the extraction sidebar, click Generate rules, check the suggested rules, then click Apply rules to start plotting.
Serial: Choose a port and baud rate. Click Rescan if your port is missing. You can also choose the text encoding and the line ending for commands you send.
J-Link RTT: Install SEGGER's J-Link Software and Documentation Pack, then restart PlotTTY. In RTT Settings, enter your microcontroller's device name. Close any other software using the J-Link probe before connecting.
The SEGGER installer includes the library needed to use the probe. On Windows,
PlotTTY looks in the standard SEGGER installation folders, so you usually don't
need to copy any DLLs. The file is JLink_x64.dll for 64-bit Python or
JLinkARM.dll for 32-bit Python.
Alternatively, add the SEGGER J-Link directory containing the DLL to your Windows
%PATH%, then restart PlotTTY.
TCP/IP: Enter the server's hostname or IP address and port. PlotTTY connects as a client. You can click Cancel while it's trying to connect.
UDP: Choose the local IP address and port to listen on. Use 0.0.0.0 to
listen on all IPv4 interfaces, or :: for IPv6. To send commands too, enter a
destination host and port using the same IP family (IPv4 or IPv6). Each command
is sent as one datagram. Leave the destination empty to receive only.
UDP doesn't guarantee delivery or order; datagrams may be lost or duplicated. PlotTTY doesn't support UDP multicast or running as a TCP server.
TCP/IP and UDP use the same text settings, extraction rules, console, and recording as Serial and RTT. Each incoming line needs a newline before PlotTTY can extract values from it. A UDP datagram ending doesn't count as a newline.
Click + or press Ctrl+T to open another tab. For example, you can monitor COM14 in one tab and COM15 in another. Each tab has its own settings, rules, plots, console history, sent commands, and recordings.
Other tabs keep receiving and recording while you're away from them. Their displays update when you return. The File and View menus apply to the selected tab.
Close a tab with Ctrl+W or its close button to disconnect and finish its recordings. Closing PlotTTY disconnects all tabs.
Extraction rules tell PlotTTY which numbers to take from each line. Paste a sample line and click Generate rules to get started, or use Add and Remove to set up rules yourself.
To create a rule manually:
- Click Add in the extraction sidebar.
- Leave Function set to Plot and choose a Method.
- Fill in the settings shown in an example below. Keep Show checked.
- Click Apply rules. New matching lines will add points to the plots.
Each example below shows a line your device might send and the settings to read it. The line must end with a newline for PlotTTY to process it.
Named values: plot every name/value pair in a line
Device output:
Voltage: 3.31, Current: 0.12, Temperature: 24.5
Add one rule with Function → Plot and Method → Named values. This method takes the labels from the line, so the rule's Label doesn't rename them. No delimiter or field number is needed.
That one rule creates three signals:
| Signal | Value |
|---|---|
| Voltage | 3.31 |
| Current | 0.12 |
| Temperature | 24.5 |
Both Voltage: 3.31 and Voltage=3.31 work. You don't need a Named values rule
for each pair; adding more would read the same values again.
Delimited values: pick columns from CSV or similar text
Device output:
12.5,3.31,0.12
Here the fields are device time in seconds, voltage, and current. Field numbers start at 0, so add these rules:
| Function | Label | Method | Delimiter | Field |
|---|---|---|---|---|
| Time | Device time | Delimited values | , |
0 |
| Plot | Voltage | Delimited values | , |
1 |
| Plot | Current | Delimited values | , |
2 |
This plots Voltage = 3.31 and Current = 0.12, both with a timestamp of 12.5 seconds. The Time rule sets the timestamp; it doesn't create a plot. Leave it out if you want to use the computer's receive time instead.
For 12.5;3.31;0.12, use ; as the delimiter. For tab-separated output, enter
\t. Add one Plot rule for each field you want to see.
First number: read a single measurement from each line
Device output:
Voltage: 3.31 V
| Function | Label | Method |
|---|---|---|
| Plot | Voltage | First number |
This plots 3.31 under the label Voltage. No other settings are needed.
It always reads the first number, even if that number is a counter or timestamp.
For example, Sample 42: Voltage 3.31 V would give 42. Use a field rule or
regex when you need a later number in the line.
Regex pattern: pick a number out of custom text
Device output:
sensor 2 | temp -4.5 C | status OK
Add a rule with Function → Plot, Label → Temperature, and Method → Regex pattern. Enter this in Pattern (or Pattern / delim. if you also have delimited rules):
temp\s+([-+]?\d+(?:\.\d+)?)This plots -4.5 as Temperature, skipping the sensor number 2.
The pattern looks for temp, followed by whitespace and a number.
The first capture group—the outer parentheses around the number—chooses the
value to plot. [-+]? allows a sign, and (?:\.\d+)? allows a decimal part
without creating another capture group.
A line without a matching temperature adds no point for this rule. Paste the pattern as shown, without quotes or extra backslashes.
Choose Plot for a signal or Time for a device timestamp in seconds. Without a Time rule, PlotTTY timestamps samples when it receives them. If you use a Time rule, lines without a valid timestamp still appear in the console but won't add points to the plots.
Uncheck Show to hide a signal; it will keep collecting data. Click its color dot to choose a color, or right-click the dot to use automatic colors again. Click Apply rules when you're done editing. The rules apply to new samples; they don't reprocess earlier data.
Each signal has a Mode selector. Analog joins the points with lines, Digital draws steps, and Dots shows the individual points. Changing the mode doesn't change the recorded data.
| Control | Action |
|---|---|
| Left-drag across a signal | Select a time range. Release to see its average. |
| Click the plot or press Escape | Clear the selection. |
| Shift + drag or middle-button drag | Move backward or forward in time. You can also drag the bottom time axis. |
| Mouse wheel | Zoom in or out around the cursor. |
| Drag the Y axis | Move the signal's value range up or down. |
| Mouse wheel over the Y axis | Zoom the signal's value range. |
| Double-click the Y axis | Reset the signal's value range. |
| Auto scroll | Follow the newest samples. |
| Fit capture | Show the whole recording. |
Hover over a plot to read the time and value at the cursor. The number in the plot header always shows the latest sample, even when you're looking at older data.
Selecting a range shows its start and end times, average, and sample count. The average uses the original samples and skips NaN and infinity. While a range is selected, the time view stays in place, but incoming data is still collected.
When you're zoomed out, PlotTTY draws fewer points to keep the plots responsive while preserving peaks. Zoom in to see individual samples. View → Diagnostics shows how many points are stored and drawn. View → Raw point limits sets when each plot mode starts drawing fewer points.
- Press Ctrl+F to search the console. Use Previous and Next to move between matches.
- Type a command and press Enter or click Send. Use Up/Down to recall commands you've sent.
- Use the View menu to show or hide panels. Drag the dividers to resize them.
- Use Clear in the console to clear text, or Clear in a plot to clear plotted data. File → Clear captured data clears both. Your saved recordings are kept.
Console history is deleted when you close the app, so turn on file logging if you need to keep it. Search looks through the whole history. You can select and copy the text currently loaded in the console. PlotTTY remembers your window layout.
Turn on View → Receive timestamps to add a time before each new line:
[1793128867.123] 136984,3,3.251200
This is the time your computer received the data, in Unix seconds with three decimal places. Lines received together share a timestamp. If a line arrives in chunks, it keeps the time of the first chunk shown in the console.
The setting is off by default. PlotTTY remembers your choice, and changing it only affects new lines. These display timestamps don't change the text used by extraction rules or the separate RX/TX timestamps in console log files.
Use File → Save profile to save your applied rules, colors, and which signals are shown. File → Open profile restores them from the saved JSON file.
File logging is off by default. To record a session, turn on File → Log to file before connecting. PlotTTY writes two files for each connection:
- A
.logfile with the console text. - A
.plottyfile with the extracted values, timestamps, labels, and source text.
Disconnect to finish the recording. Use File → Load capture to open a
.plotty file, or File → Export capture as CSV to use its values in another
tool. CSV export needs a finished recording; CSV import isn't supported.
Recordings are saved in logs/ under the app's working directory. Hover over
Log to file to see the full folder path, or over the recording status to see
the file paths. You can cancel loading or exporting a capture.
Serial baud rate choices are 9,600, 19,200, 38,400, 57,600, 115,200, 230,400, 460,800, and 921,600. Which rates work depends on your device and driver.
The status bar shows received bytes per second. That's different from baud rate or the number of plotted values per second. USB CDC devices can send faster than the selected baud rate when they send USB packets directly. For a physical UART using 8N1, 115,200 baud allows up to 11,520 payload bytes/s; 921,600 baud allows 92,160 bytes/s.
| Test | Result |
|---|---|
| USB CDC input | About 690–720 kB/s at 10,000 text records/s, with five plotted values per record (50,000 values/s). Console output and file recording were enabled. |
| Stored points | 1,000,000 points across five signals (200,000 each) in synthetic plotting tests. |
| Plot refresh | A refresh is scheduled every 33 ms. Actual timing depends on the data, plot mode, window size, and computer. |
The USB test ran on Windows with a physical STM32 sending simulated data, a 1280 × 720 window, and repeated panning and zooming. These figures aren't a guaranteed maximum. Some console search, scroll, and copy stress tests had occasional missing records. The million-point test used synthetic data separately from live recording.
There's no fixed limit on the number of stored points; available memory and disk space set the practical limit. PlotTTY keeps raw samples in temporary files and draws fewer points when zoomed out. Zooming in shows individual samples, and averages always use the original data.
Install Python 3.13, then run these commands from the project folder on Windows:
python -m venv .venv
.venv\Scripts\python.exe -m pip install -r requirements.txt
.venv\Scripts\python.exe mainwindow.pyPlotTTY is licensed under the MIT License. Third-party licenses are listed in THIRD_PARTY_NOTICES.txt and included with packaged releases.